» Articles » PMID: 24166880

A Method for Evaluating the Use of Fluorescent Dyes to Track Proliferation in Cell Lines by Dye Dilution

Overview
Journal Cytometry A
Specialties Cell Biology
Radiology
Date 2013 Oct 30
PMID 24166880
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Labeling nonquiescent cells with carboxyfluorescein succinimidyl ester (CFSE)-like dyes gives rise to a population width exceeding the threshold for resolving division peaks by flow cytometry. Width is a function of biological heterogeneity plus extrinsic and intrinsic error sources associated with the measurement process. Optimal cytometer performance minimizes extrinsic error, but reducing intrinsic error to the point of facilitating peak resolution requires careful fluorochrome selection and fluorescent cell sorting. In this study, we labeled the Jurkat and A549 cell lines with CFSE, CellTraceViolet (CTV), and eFluor 670 proliferation dye (EPD) to test if we could resolve division peaks in culture after reducing the labeled input widths by cell sorting. Reanalysis of the sorted populations to ascertain the level of reduction achieved always led to widths exceeding the gated limits due to the contribution of errors. Measuring detector-specific extrinsic error by sorting uniform fluorescent particles with similar spectral properties to the tracking dyes allowed us to determine the intrinsic error for each dye and cell type using a simple mathematical approach. We found that cell intrinsic error ultimately dictated whether we could resolve division peaks, and that as this increased, the required sort gate width to resolve any division peaks decreased to the point whereby issues with yield made A549 unsuitable for this approach. Finally, attempts to improve yields by setting two concurrent sort gates on the fluorescence distribution enriched for cells in different stages of the cell cycle that had nonequivalent proliferative properties in culture and thus should be practiced with caution.

Citing Articles

Multicolor iLIFE (m-iLIFE) volume cytometry for high-throughput imaging of multiple organelles.

Kumar P, Mondal P Sci Rep. 2024; 14(1):23798.

PMID: 39394224 PMC: 11470118. DOI: 10.1038/s41598-024-73667-3.


Methods to Assess Proliferation of Stimulated Human Lymphocytes In Vitro: A Narrative Review.

Ganesan N, Ronsmans S, Hoet P Cells. 2023; 12(3).

PMID: 36766728 PMC: 9913443. DOI: 10.3390/cells12030386.


FASCIA Method in the Assessment of Lymphocyte Mitogen Responses in the Laboratory Diagnostics of Primary Immunodeficiencies.

Lusila P, Toivonen A, Jarva H, Vettenranta K, Lehtimaki S, Kekalainen E J Clin Immunol. 2022; 43(3):653-661.

PMID: 36512178 PMC: 9958160. DOI: 10.1007/s10875-022-01417-z.


Data Driven Cell Cycle Model to Quantify the Efficacy of Cancer Therapeutics Targeting Specific Cell-Cycle Phases From Flow Cytometry Results.

James D, Filby A, Brown M, Summers H, Francis L, Rees P Front Bioinform. 2022; 1:662210.

PMID: 36303763 PMC: 9581040. DOI: 10.3389/fbinf.2021.662210.


3D Bioprinted Spheroidal Droplets for Engineering the Heterocellular Coupling between Cardiomyocytes and Cardiac Fibroblasts.

El Khoury R, Nagiah N, Mudloff J, Thakur V, Chattopadhyay M, Joddar B Cyborg Bionic Syst. 2022; 2021.

PMID: 35795473 PMC: 9254634. DOI: 10.34133/2021/9864212.