» Articles » PMID: 24154920

NiTi Superelastic Orthodontic Archwires with Polyamide Coating

Overview
Publisher Springer
Date 2013 Oct 25
PMID 24154920
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Twenty orthodontic archwires with 55.2% Ni and 44.8% Ti (% weight) were subjected to a dipping treatment to coat the NiTi surface by a polyamide polymer. It has been selected a Polyamide 11 due to its remarkable long lasting performance. The transformation temperatures as well as the transformation stresses of the NiTi alloy were determined in order to know whether the coating process can alter its properties. The adhesive wear tests have been demonstrated that the wear rates as well as the dynamic friction coefficients μ of polymer coated wires are much lower than metallic wires. The corrosion studies have shown that the use of this polymer, as coating, seals the NiTi surface to prevent corrosion and the release of nickel ions. The average decrease of Ni ions release due to this coating is around 85%.

Citing Articles

Surface Coating of Nickel-Titanium (Ni-Ti) Pediatric Rotary File Using Graphene Oxide: A Scanning Electron Microscopy Analysis.

Panja K, A V, N V, Ramar K Cureus. 2024; 16(8):e66632.

PMID: 39258062 PMC: 11386944. DOI: 10.7759/cureus.66632.


Tribology of Coated 316L SS by Various Nanoparticles.

Aldabagh D, Alzubadi T, Alhuwaizi A Int J Biomater. 2023; 2023:6676473.

PMID: 37649637 PMC: 10465258. DOI: 10.1155/2023/6676473.


In vitro wearing away of orthodontic brackets and wires in different conditions: A review.

Espinoza-Montero P, Montero-Jimenez M, Fernandez L, Paz J, Pineiros J, Ceballos S Heliyon. 2022; 8(9):e10560.

PMID: 36325428 PMC: 9621092. DOI: 10.1016/j.heliyon.2022.e10560.


Polymeric materials and films in dentistry: An overview.

Rokaya D, Srimaneepong V, Sapkota J, Qin J, Siraleartmukul K, Siriwongrungson V J Adv Res. 2018; 14:25-34.

PMID: 30364755 PMC: 6198729. DOI: 10.1016/j.jare.2018.05.001.


Bacterial colonization on coated and uncoated orthodontic wires: A prospective clinical trial.

Raji S, Shojaei H, Saeidi Ghorani P, Rafiei E Dent Res J (Isfahan). 2014; 11(6):680-3.

PMID: 25540663 PMC: 4275637.


References
1.
Walker M, White R, Kula K . Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires. Am J Orthod Dentofacial Orthop. 2005; 127(6):662-9. DOI: 10.1016/j.ajodo.2005.01.015. View

2.
Gurgel J, Pinzan-Vercelino C, Powers J . Mechanical properties of beta-titanium wires. Angle Orthod. 2011; 81(3):478-83. PMC: 8923551. DOI: 10.2319/070510-379.1. View

3.
Setcos J, Babaei-Mahani A, Di Silvio L, Mjor I, Wilson N . The safety of nickel containing dental alloys. Dent Mater. 2006; 22(12):1163-8. DOI: 10.1016/j.dental.2005.11.033. View

4.
Abalos C, Paul A, Mendoza A, Solano E, Gil F . Influence of topographical features on the fluoride corrosion of Ni-Ti orthodontic archwires. J Mater Sci Mater Med. 2011; 22(12):2813-21. DOI: 10.1007/s10856-011-4460-y. View

5.
Villermaux F, Tabrizian M, Yahia L, Czeremuszkin G, Piron D . Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating. Biomed Mater Eng. 1996; 6(4):241-54. View