The Effects of Loading Conditions and Specimen Environment on the Nanomechanical Response of Canine Cortical Bone

Overview
Publisher Elsevier
Date 2013 Oct 8
PMID 24094163
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Bone is a viscoelastic connective tissue composed primarily of mineral and type I collagen, which interacts with water, affecting its mechanical properties. Therefore, both the level of hydration and the loading rate are expected to influence the measured nanomechanical response of bone. In this study, we investigated the influence of three distinct hydration conditions, peak loads and loading/unloading rates on the elastic modulus and hardness of canine femoral cortical bone via nanoindentation. Sections from three canine femurs from multiple regions of the diaphysis were tested for a total of 670 indentations. All three hydration conditions (dry, moist and fully hydrated tissue) were tested at three different loading profiles (a triangular loading profile with peak loads of 600, 800 and 1000 μN at loading/unloading rate of 60, 80 and 100 μN/s, respectively; each test was 20s in duration). Significant differences were found for both the elastic modulus and hardness between the dry, moist and fully hydrated conditions (p≤0.02). For dry bone, elastic modulus and hardness values were not found to be significantly different between the different loading profiles (p>0.05). However, in both the moist and fully hydrated conditions, the elastic modulus and hardness were significantly different under all loading profiles (with the exception of the moist condition at the 600- and 800-μN peak load). Given these findings, it is critical to perform nanoindentation of bone under fully hydrated conditions to ensure physiologically relevant results. Furthermore, this work found that a 20-s triangular loading/unloading profile was sufficient to capture the viscoelastic behavior of bone in the 600- to 1000-μN peak load range. Lastly, specific peak load values and loading rates need to be selected based on the structural region for which the mechanical properties are to be measured.

Citing Articles

Tailoring the multiscale mechanics of tunable decellularized extracellular matrix (dECM) for wound healing through immunomodulation.

Luo P, Huang R, Wu Y, Liu X, Shan Z, Gong L Bioact Mater. 2023; 28:95-111.

PMID: 37250862 PMC: 10209339. DOI: 10.1016/j.bioactmat.2023.05.011.


Engineering 3D Printed Bioceramic Scaffolds to Reconstruct Critical-Sized Calvaria Defects in a Skeletally Immature Pig Model.

DeMitchell-Rodriguez E, Shen C, Nayak V, Tovar N, Witek L, Torroni A Plast Reconstr Surg. 2023; 152(2):270e-280e.

PMID: 36723712 PMC: 11310574. DOI: 10.1097/PRS.0000000000010258.


Biomechanical Test of a New Endoprosthesis for Cylindrical Medullary Canals in Dogs.

Mendaza-DeCal R, Ballesteros Y, Peso-Fernandez S, Paz E, Del Real-Romero J, Rodriguez-Quiros J Front Vet Sci. 2022; 9:887676.

PMID: 35847635 PMC: 9280675. DOI: 10.3389/fvets.2022.887676.


Angiogenesis, Osseointegration, and Antibacterial Applications of Polyelectrolyte Multilayer Coatings Incorporated With Silver/Strontium Containing Mesoporous Bioactive Glass on 316L Stainless Steel.

Kuo Y, Chen C, Dash P, Lin Y, Hsu C, Shih S Front Bioeng Biotechnol. 2022; 10:818137.

PMID: 35223788 PMC: 8879691. DOI: 10.3389/fbioe.2022.818137.


Histological and Nanomechanical Properties of a New Nanometric Hydroxiapatite Implant Surface. An In Vivo Study in Diabetic Rats.

Oliveira P, Coelho P, Bergamo E, Witek L, Borges C, Bezerra F Materials (Basel). 2020; 13(24).

PMID: 33322243 PMC: 7764315. DOI: 10.3390/ma13245693.