Abstract

Purpose: (153)Sm-ethylene diamine tetramethylene phosphonic acid ((153)Sm-EDTMP) is widely used to palliate pain from bone metastases, and is being studied for combination therapy beyond palliation. Conceptually, red marrow (RM) dosimetry allows myelotoxicity to be predicted, but the correlation is poor due to dosimetric uncertainty, individual sensitivity and biological effects from previous treatments. According to EANM guidelines, basic dosimetric procedures have been studied to improve the correlation between dosimetry and myelotoxicity in (153)Sm-EDTMP therapy.

Methods: RM dosimetry for 33 treatments of bone metastases from breast, prostate and lung tumours was performed prospectively (with (99m)Tc-MDP) and retrospectively, acquiring whole-body scans early and late after injection. The (153)Sm-EDTMP activity was calculated by prospective dosimetry based on measured skeletal uptake and full physical retention, with the RM absorbed dose not exceeding 3.8 Gy. Patient-specific RM mass was evaluated by scaling in terms of body weight (BW), lean body mass (LBM) and trabecular volume (TV) estimated from CT scans of the L2–L4 vertebrae. Correlations with toxicity were determined in a selected subgroup of 27 patients, in which a better correlation between dosimetry and myelotoxicity was expected.

Results: Skeletal uptakes of (99m)Tc and (153)Sm (Tc% and Sm%) were well correlated. The median Sm% was higher in prostate cancer (75.3 %) than in lung (60.5%, p = 0.005) or breast (60.8%, p = 0.008). PLT and WBC nadirs were not correlated with administered activity, but were weakly correlated with uncorrected RM absorbed doses, and the correlation improved after rescaling in terms of BW, LBM and TV. Most patients showed transient toxicity (grade 1–3), which completely and spontaneously recovered over a few days. Using TV, RM absorbed dose was in the range 2–5 Gy, with a median of 312 cGy for PLT in patients with toxicity and 247 cGy in those with no toxicity (p = 0.019), and 312 cGy for WBC in those with toxicity and 232 cGy in those with no toxicity (p = 0.019). ROC curves confirmed the correlations, yielding toxicity absorbed dose thresholds of 265 cGy for PLT and 232 cGy for WBC.

Conclusion: The best predictor of myelotoxicity and blood cells nadir was obtained scaling the RM absorbed dose in terms of the estimated TV. It seems clear that the increase in skeletal uptake due to the presence of bone metastases and the assumption of full physical retention cause an overestimation of the RM absorbed dose. Nevertheless, an improvement of the dose–toxicity correlation is easily achievable by simple methods, also leading to possible improvement in multifactorial analyses of myelotoxicity.

Citing Articles

Personalized Dosimetry in Targeted Radiation Therapy: A Look to Methods, Tools and Critical Aspects.

Danieli R, Milano A, Gallo S, Veronese I, Lascialfari A, Indovina L J Pers Med. 2022; 12(2).

PMID: 35207693 PMC: 8874397. DOI: 10.3390/jpm12020205.


Disturbance of cellular homeostasis as a molecular risk evaluation of human endothelial cells exposed to nanoparticles.

Wigner P, Zielinski K, Michlewska S, Danielska P, Marczak A, Ricci E Sci Rep. 2021; 11(1):3849.

PMID: 33589697 PMC: 7884700. DOI: 10.1038/s41598-021-83291-0.


Recent Progress in the Theranostics Application of Nanomedicine in Lung Cancer.

Mukherjee A, Paul M, Mukherjee S Cancers (Basel). 2019; 11(5).

PMID: 31035440 PMC: 6562381. DOI: 10.3390/cancers11050597.


Correlation of dose with toxicity and tumour response to Y- and Lu-PRRT provides the basis for optimization through individualized treatment planning.

Cremonesi M, Ferrari M, Bodei L, Chiesa C, Sarnelli A, Garibaldi C Eur J Nucl Med Mol Imaging. 2018; 45(13):2426-2441.

PMID: 29785514 PMC: 6716520. DOI: 10.1007/s00259-018-4044-x.


Dosimetry-Based Consideration on Remission and Relapse after Therapy with Ra-Dichloride in Castration-Resistant Prostate Cancer (CRPC) with Bone Metastases. A Case Report.

Mangano A, Pacilio M, Ialongo P, Semprebene A, Ventroni G, Mango L Diagnostics (Basel). 2018; 8(1).

PMID: 29495541 PMC: 5872001. DOI: 10.3390/diagnostics8010018.


References
1.
Suttmann H, Grgic A, Lehmann J, Zwergel U, Kamradt J, Gouverneur E . Combining 153Sm-lexidronam and docetaxel for the treatment of patients with hormone-refractory prostate cancer: first experience. Cancer Biother Radiopharm. 2008; 23(5):609-18. DOI: 10.1089/cbr.2008.0487. View

2.
Bauman G, Charette M, Reid R, Sathya J . Radiopharmaceuticals for the palliation of painful bone metastasis-a systemic review. Radiother Oncol. 2005; 75(3):258-70. DOI: 10.1016/j.radonc.2005.03.003. View

3.
Behr T, Behe M, Sgouros G . Correlation of red marrow radiation dosimetry with myelotoxicity: empirical factors influencing the radiation-induced myelotoxicity of radiolabeled antibodies, fragments and peptides in pre-clinical and clinical settings. Cancer Biother Radiopharm. 2002; 17(4):445-64. DOI: 10.1089/108497802760363231. View

4.
ODonoghue J, Baidoo N, Deland D, Welt S, Divgi C, Sgouros G . Hematologic toxicity in radioimmunotherapy: dose-response relationships for I-131 labeled antibody therapy. Cancer Biother Radiopharm. 2002; 17(4):435-43. DOI: 10.1089/108497802760363222. View

5.
Hindorf C, Glatting G, Chiesa C, Linden O, Flux G . EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry. Eur J Nucl Med Mol Imaging. 2010; 37(6):1238-50. DOI: 10.1007/s00259-010-1422-4. View