A Longer Waiting Game: Bridging Children to Heart Transplant with the Berlin Heart EXCOR Device--the United Kingdom Experience

Abstract

Background: Mechanical circulatory support (MCS) is used to support children with end-stage heart failure to heart transplant.

Methods: This was a retrospective cohort study of 7 years' experience with the Berlin Heart (BH) EXCOR (Berlin Heart AG, Berlin Germany) paracorporeal ventricular assist device (VAD) in 2 United Kingdom (UK) pediatric heart transplant centers and the effect of this program on the UK pediatric heart transplant service.

Results: Of 102 children who received BH support, 84% survived to transplant or BH explant and 81% survived to discharge. Neither age nor duration of support influenced outcome. Stroke, ongoing requirement for ventilation while on BH, and diagnosis other than dilated cardiomyopathy were the only independent mortality risk factors. Children who weighed < 20 kg had significantly (p = 0.03) longer support times than bigger children. The number of children treated with a BH increased over time (p = 0.01). Currently > 50% of pediatric heart transplants are bridged with a BH; however, pediatric transplants per year have not increased significantly (p = 0.07) CONCLUSIONS: BH use in the UK has allowed significant increases in the number of children with end-stage heart failure who can be successfully bridged to transplant and the length of time they can be supported. The total number of transplants has not increased.

Citing Articles

Cerebrovascular accidents in paediatric patients supported by the Berlin Heart EXCOR.

Rohde S, Sandica E, Veen K, Miera O, Amodeo A, Napoleone C Eur J Cardiothorac Surg. 2022; 62(3).

PMID: 35849328 PMC: 9789740. DOI: 10.1093/ejcts/ezac381.


Pediatric Restrictive Cardiomyopathies.

Ditaranto R, Caponetti A, Ferrara V, Parisi V, Minnucci M, Chiti C Front Pediatr. 2022; 9:745365.

PMID: 35145940 PMC: 8822222. DOI: 10.3389/fped.2021.745365.


The Waiting List Mortality of Pediatric Heart Transplantation Candidates in Korea before the Pediatric Ventricular Assist Device Era.

Jeung M, Kim M, Huh J, Kang I, Kim G, Yu J J Korean Med Sci. 2021; 36(44):e283.

PMID: 34783215 PMC: 8593407. DOI: 10.3346/jkms.2021.36.e283.


Experience with Temporary Centrifugal Pump Bi-ventricular Assist Device for Pediatric Acute Heart Failure: Comparison with ECMO.

Lim J, Kwak J, Min J, Kwon H, Song M, Kim G Pediatr Cardiol. 2020; 41(8):1559-1568.

PMID: 32856126 PMC: 7451784. DOI: 10.1007/s00246-020-02412-0.


The First Pediatric Heart Transplantation Bridged by a Durable Left Ventricular Assist Device in Korea.

Shin J, Park H, Jung S, Kim A, Jung J, Shin Y Korean J Thorac Cardiovasc Surg. 2020; 53(2):79-81.

PMID: 32309207 PMC: 7155184. DOI: 10.5090/kjtcs.2020.53.2.79.