» Articles » PMID: 24058034

Red Blood Cell Tracking Using Optical Flow Methods

Overview
Date 2013 Sep 24
PMID 24058034
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The investigation of microcirculation is an important task in biomedical and physiological research because the microcirculation information, such as flow velocity and vessel density, is critical to monitor human conditions and develop effective therapies of some diseases. As one of the tasks of the microcirculation study, red blood cell (RBC) tracking presents an effective approach to estimate some parameters in microcirculation. The common method for RBC tracking is based on spatiotemporal image analysis, which requires the image to have high qualification and cells should have fixed velocity. Besides, for in vivo cell tracking, cells may disappear in some frames, image series may have spatial and temporal distortions, and vessel distribution can be complex, which increase the difficulties of RBC tracking. In this paper, we propose an optical flow method to track RBCs. It attempts to describe the local motion for each visible point in the frames using a local displacement vector field. We utilize it to calculate the displacement of a cell in two adjacent frames. Additionally, another optical flow-based method, scale invariant feature transform (SIFT) flow, is also presented. The experimental results show that optical flow is quite robust to the case where the velocity of cell is unstable, while SIFT flow works well when there is a large displacement of the cell between two adjacent frames. Our proposed methods outperform other methods when doing in vivo cell tracking, which can be used to estimate the blood flow directly and help to evaluate other parameters in microcirculation.

Citing Articles

Optical Flow-Based Full-Field Quantitative Blood-Flow Velocimetry Using Temporal Direction Filtering and Peak Interpolation.

Meng L, Huang M, Feng S, Wang Y, Lu J, Li P Int J Mol Sci. 2023; 24(15).

PMID: 37569421 PMC: 10419297. DOI: 10.3390/ijms241512048.


Cross-Ray Ultrasound Tomography and Photoacoustic Tomography of Cerebral Hemodynamics in Rodents.

Na S, Zhang Y, Wang L Adv Sci (Weinh). 2022; 9(25):e2201104.

PMID: 35818697 PMC: 9443457. DOI: 10.1002/advs.202201104.


Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo.

Meng G, Zhong J, Zhang Q, Wong J, Wu J, Tsia K Proc Natl Acad Sci U S A. 2022; 119(23):e2117346119.

PMID: 35648820 PMC: 9191662. DOI: 10.1073/pnas.2117346119.


Cell Trafficking at the Intersection of the Tumor-Immune Compartments.

Du W, Nair P, Johnston A, Wu P, Wirtz D Annu Rev Biomed Eng. 2022; 24:275-305.

PMID: 35385679 PMC: 9811395. DOI: 10.1146/annurev-bioeng-110320-110749.


Temporally coherent cardiac motion tracking from cine MRI: Traditional registration method and modern CNN method.

Qiao M, Wang Y, Guo Y, Huang L, Xia L, Tao Q Med Phys. 2020; 47(9):4189-4198.

PMID: 32564357 PMC: 7586816. DOI: 10.1002/mp.14341.


References
1.
Levy B, Ambrosio G, Pries A, Struijker-Boudier H . Microcirculation in hypertension: a new target for treatment?. Circulation. 2001; 104(6):735-40. DOI: 10.1161/hc3101.091158. View

2.
Mawson D, Shore A . Comparison of CapiFlow and frame by frame analysis for the assessment of capillary red blood cell velocity. J Med Eng Technol. 1998; 22(2):53-63. DOI: 10.3109/03091909809010000. View

3.
Chang C, Tsai R, Wu W, KUO S, Yu H . Use of dynamic capillaroscopy for studying cutaneous microcirculation in patients with diabetes mellitus. Microvasc Res. 1997; 53(2):121-7. DOI: 10.1006/mvre.1996.2003. View

4.
Liu C, Yuen J, Torralba A . SIFT flow: dense correspondence across scenes and its applications. IEEE Trans Pattern Anal Mach Intell. 2010; 33(5):978-94. DOI: 10.1109/TPAMI.2010.147. View

5.
Tseng C, Chong C, Chen C, Lin B, Tai T . Abnormal peripheral microcirculation in seemingly normal subjects living in blackfoot-disease-hyperendemic villages in Taiwan. Int J Microcirc Clin Exp. 1995; 15(1):21-7. DOI: 10.1159/000178945. View