» Articles » PMID: 24046072

Increasing Spatial Resolution of 3T MRI Scanning Improves Reproducibility of Carotid Arterial Wall Dimension Measurements

Overview
Journal MAGMA
Publisher Springer
Date 2013 Sep 19
PMID 24046072
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To improve carotid 3T magnetic resonance imaging (MRI) dimension measurements in patients with overt atherosclerotic carotid artery disease.

Materials And Methods: In 31 patients with advanced atherosclerotic carotid artery disease, two high resolution (0.25 × 0.25 mm(2); HR) and two routinely used low resolution (0.50 × 0.50 mm(2); LR) carotid 3T MRI scans were performed within 1 month. After manual delineation of carotid wall contours in a dedicated image analyses program in eight slices covering the atherosclerotic plaque, image reproducibility, as well as the within-reader and between-reader variability were determined.

Results: We found significantly higher intraclass correlation coefficients for total wall volume, mean wall area and mean wall thickness for the HR measurements (all p < 0.05). We found a significant lower signal-to-noise and contrast-to-noise ratio for the HR compared to the LR measurements. The carotid arterial wall dimension measurements of all parameters were significantly lower for the HR compared to the LR measurements. No significant differences were observed between the within-reader and between-reader reproducibility for HR versus LR measurements.

Conclusion: Increasing the in-plane resolution improves the reproducibility of 3T MRI carotid arterial wall dimension measurements. The use of HR imaging will contribute to a reduced sample size needed in intervention trials using MRI scanning of the carotid artery as surrogate marker for atherosclerosis progression.

Citing Articles

Molecular imaging of cellular immunotherapies in experimental and therapeutic settings.

Shalaby N, Dubois V, Ronald J Cancer Immunol Immunother. 2021; 71(6):1281-1294.

PMID: 34657195 PMC: 9122865. DOI: 10.1007/s00262-021-03073-5.


Quantitative assessment of carotid artery atherosclerosis by three-dimensional magnetic resonance and two-dimensional ultrasound imaging: a comparison study.

Qiao H, Cai Y, Huang M, Liu Y, Zhang Q, Huang L Quant Imaging Med Surg. 2020; 10(5):1021-1032.

PMID: 32489926 PMC: 7242289. DOI: 10.21037/qims-19-818.


Comparison of four MR carotid surface coils at 3T.

Zhang Q, Coolen B, van den Berg S, Kotek G, Rivera D, Klomp D PLoS One. 2019; 14(3):e0213107.

PMID: 30830934 PMC: 6398924. DOI: 10.1371/journal.pone.0213107.


Quantitative 3D dynamic contrast-enhanced (DCE) MR imaging of carotid vessel wall by fast T1 mapping using Multitasking.

Wang N, Christodoulou A, Xie Y, Wang Z, Deng Z, Zhou B Magn Reson Med. 2018; 81(4):2302-2314.

PMID: 30368891 PMC: 6372333. DOI: 10.1002/mrm.27553.


Manual versus Automated Carotid Artery Plaque Component Segmentation in High and Lower Quality 3.0 Tesla MRI Scans.

Smits L, van Wijk D, Duivenvoorden R, Xu D, Yuan C, Stroes E PLoS One. 2016; 11(12):e0164267.

PMID: 27930665 PMC: 5145140. DOI: 10.1371/journal.pone.0164267.


References
1.
Meuwese M, de Groot E, Duivenvoorden R, Trip M, Ose L, Maritz F . ACAT inhibition and progression of carotid atherosclerosis in patients with familial hypercholesterolemia: the CAPTIVATE randomized trial. JAMA. 2009; 301(11):1131-9. DOI: 10.1001/jama.301.11.1131. View

2.
Kastelein J, Akdim F, Stroes E, Zwinderman A, Bots M, Stalenhoef A . Simvastatin with or without ezetimibe in familial hypercholesterolemia. N Engl J Med. 2008; 358(14):1431-43. DOI: 10.1056/NEJMoa0800742. View

3.
Duivenvoorden R, de Groot E, Elsen B, Lameris J, van der Geest R, Stroes E . In vivo quantification of carotid artery wall dimensions: 3.0-Tesla MRI versus B-mode ultrasound imaging. Circ Cardiovasc Imaging. 2009; 2(3):235-42. DOI: 10.1161/CIRCIMAGING.108.788059. View

4.
Koktzoglou I, Chung Y, Mani V, Carroll T, Morasch M, Mizsei G . Multislice dark-blood carotid artery wall imaging: a 1.5 T and 3.0 T comparison. J Magn Reson Imaging. 2006; 23(5):699-705. DOI: 10.1002/jmri.20563. View

5.
Alizadeh Dehnavi R, Doornbos J, Tamsma J, Stuber M, Putter H, van der Geest R . Assessment of the carotid artery by MRI at 3T: a study on reproducibility. J Magn Reson Imaging. 2007; 25(5):1035-43. DOI: 10.1002/jmri.20904. View