» Articles » PMID: 24045456

High Speed Versus Pulsed Images for Micro-particle Image Velocimetry: a Direct Comparison of Red Blood Cells Versus Fluorescing Tracers As Tracking Particles

Overview
Journal Physiol Meas
Date 2013 Sep 19
PMID 24045456
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

High speed photography in micro-particle image velocimetry (μPIV) using red blood cells as tracer particles and the use of fluorescing tracer particles (in conjunction with pulsed images) are directly compared by using both methods simultaneously. Measurements are taken on the same blood sample in the same microchip using both methods. This work directly and statistically compares the two methods of μPIV measurement in a controlled in vitro environment for the first time in literature. The pulsed method using fluorescing tracer particles is found to decrease the depth of correlation as expected, and to better represent the shape of the velocity profile. Two methods of velocity characterization are used (single and double parameter) and the pulsed images provide better shape representation in both cases.

Citing Articles

Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows.

Le A, Fenech M Front Physiol. 2022; 13:886675.

PMID: 35574441 PMC: 9099138. DOI: 10.3389/fphys.2022.886675.


Microfluidics Approach to the Mechanical Properties of Red Blood Cell Membrane and Their Effect on Blood Rheology.

Trejo-Soto C, Lazaro G, Pagonabarraga I, Hernandez-Machado A Membranes (Basel). 2022; 12(2).

PMID: 35207138 PMC: 8878405. DOI: 10.3390/membranes12020217.