We propose a methodology for evaluation of agreement between two methods of measuring a continuous variable whose variability changes with magnitude. This problem routinely arises in method comparison studies that are common in health-related disciplines. Assuming replicated measurements, we first model the data using a heteroscedastic mixed-effects model, wherein a suitably defined true measurement serves as the variance covariate. Fitting this model poses some computational difficulties as the likelihood function is not available in a closed form. We deal with this issue by suggesting four estimation methods to obtain approximate maximum likelihood estimates. Two of these methods are based on numerical approximation of the likelihood, and the other two are based on approximation of the model. Next, we extend the existing agreement evaluation methodology designed for homoscedastic data to work under the proposed heteroscedastic model. This methodology can be used with any scalar measure of agreement. Simulations show that the suggested inference procedures generally work well for moderately large samples. They are illustrated by analyzing a data set of cholesterol measurements.

Citing Articles

Agreement between manual and automatic ultrasound measurement of the velocity-time integral in the left ventricular outflow tract in intensive care patients: evaluation of the AUTO-VTI® tool.

Louart B, Muller L, Emond B, Boulet N, Roger C J Clin Monit Comput. 2024; .

PMID: 39287731 DOI: 10.1007/s10877-024-01215-5.


The Bland-Altman method should not be used when one of the two measurement methods has negligible measurement errors.

Taffe P, Zuppinger C, Burger G, Nussle S PLoS One. 2022; 17(12):e0278915.

PMID: 36508421 PMC: 9744297. DOI: 10.1371/journal.pone.0278915.


Bedside monitoring of lung volume available for gas exchange.

Tran M, Crockett D, Cronin J, Borges J, Hedenstierna G, Larsson A Intensive Care Med Exp. 2021; 9(1):3.

PMID: 33496887 PMC: 7835652. DOI: 10.1186/s40635-020-00364-6.


An Extension of the Bland-Altman Plot for Analyzing the Agreement of More than Two Raters.

Moller S, Debrabant B, Halekoh U, Petersen A, Gerke O Diagnostics (Basel). 2021; 11(1).

PMID: 33401454 PMC: 7824071. DOI: 10.3390/diagnostics11010054.


Reliability of Myotonometric Measurement of Stiffness in Patients with Spinal Cord Injury.

Ge J, Chang T, Zhang Z Med Sci Monit. 2020; 26:e924811.