» Articles » PMID: 24000982

Four-dimensional (4D) Motion Detection to Correct Respiratory Effects in Treatment Response Assessment Using Molecular Imaging Biomarkers

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Observing early metabolic changes in positron emission tomography (PET) is an essential tool to assess treatment efficiency in radiotherapy. However, for thoracic regions, the use of three-dimensional (3D) PET imaging is unfeasible because the radiotracer activity is smeared by the respiratory motion and averaged during the imaging acquisition process. This motion-induced degradation is similar in magnitude with the treatment-induced changes, and the two occurrences become indiscernible. We present a customized temporal-spatial deformable registration method for quantifying respiratory motion in a four-dimensional (4D) PET dataset. Once the motion is quantified, a motion-corrected (MC) dataset is created by tracking voxels to eliminate breathing-induced changes in the 4D imaging scan. The 4D voxel-tracking data is then summed to yield a 3D MC-PET scan containing only treatment-induced changes. This proof of concept is exemplified on both phantom and clinical data, where the proposed algorithm tracked the trajectories of individual points through the 4D datasets reducing motion to less than 4 mm in all phases. This correction approach using deformable registration can discern motion blurring from treatment-induced changes in treatment response assessment using PET imaging.

References
1.
Li T, Thorndyke B, Schreibmann E, Yang Y, Xing L . Model-based image reconstruction for four-dimensional PET. Med Phys. 2006; 33(5):1288-98. DOI: 10.1118/1.2192581. View

2.
Lee L, Ma Y, Ye Y, Xing L . Conceptual formulation on four-dimensional inverse planning for intensity modulated radiation therapy. Phys Med Biol. 2009; 54(13):N255-66. DOI: 10.1088/0031-9155/54/13/N01. View

3.
Rueckert D, Sonoda L, Hayes C, Hill D, Leach M, Hawkes D . Nonrigid registration using free-form deformations: application to breast MR images. IEEE Trans Med Imaging. 1999; 18(8):712-21. DOI: 10.1109/42.796284. View

4.
Dawood M, Buther F, Jiang X, Schafers K . Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging. 2008; 27(8):1164-75. DOI: 10.1109/TMI.2008.918321. View

5.
Ledesma-Carbayo M, Kybic J, Desco M, Santos A, Suhling M, Hunziker P . Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation. IEEE Trans Med Imaging. 2005; 24(9):1113-26. DOI: 10.1109/TMI.2005.852050. View