» Articles » PMID: 23989858

Ulnar Variance As a Predictor of Persistent Instability Following Galeazzi Fracture-dislocations

Overview
Date 2013 Aug 31
PMID 23989858
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: We investigated the radiographic parameters that may predict distal radial ulnar joint (DRUJ) instability in surgically treated radial shaft fractures. In our clinical experience, there are no previously reported radiographic parameters that are universally predictive of DRUJ instability following radial shaft fracture.

Materials And Methods: Fifty consecutive patients, ages 20-79 years, with unilateral radial shaft fractures and possible associated DRUJ injury were retrospectively identified over a 5-year period. Distance from radial carpal joint (RCJ) to fracture proportional to radial shaft length, ulnar variance, and ulnar styloid fractures were correlated with DRUJ instability after surgical treatment.

Results: Twenty patients had persistent DRUJ incongruence/instability following fracture fixation. As a proportion of radial length, the distance from the RCJ to the fracture line did not significantly differ between those with persistent DRUJ instability and those without (p = 0.34). The average initial ulnar variance was 5.5 mm (range 2-12 mm, SD = 3.2) in patients with DRUJ instability and 3.8 mm (range 0-11 mm, SD = 3.5) in patients without. Only 4/20 patients (20%) with DRUJ instability had normal ulnar variance (-2 to +2 mm) versus 15/30 (50%) patients without (p = 0.041).

Conclusion: In the setting of a radial shaft fracture, ulnar variance greater or less than 2 mm was associated with a greater likelihood of DRUJ incongruence/instability following fracture fixation.

Citing Articles

Headless screw fixation of unstable ulnar styloid base fractures after distal radial fractures fixation.

Goorens C, Van Eetvelde G, Debaenst N, Van Royen K, Goubau J J Hand Microsurg. 2024; 16(4):100066.

PMID: 39234369 PMC: 11369729. DOI: 10.1016/j.jham.2024.100066.


A Unique "Galeazzi-Like" Fracture through a Vacated External-Fixator Pin Track: A Case Report.

Meyer P, Kadiyala M, Egol K J Orthop Case Rep. 2024; 14(7):108-112.

PMID: 39035396 PMC: 11258733. DOI: 10.13107/jocr.2024.v14.i07.4594.


A Case of Bilateral Galeazzi Fracture-Dislocations.

Panagopoulos A, Solou K, Tatani I, Kouzelis A, Kokkalis Z Cureus. 2021; 13(8):e17491.

PMID: 34603873 PMC: 8476194. DOI: 10.7759/cureus.17491.


Higher-Than-Expected Rates of Distal Radioulnar Joint Fixation in Radial Shaft Fractures: Location of Fracture Matters.

Zhang J, Samineni A, Sing D, Rothman A, Stein A Hand (N Y). 2021; 18(2):328-334.

PMID: 33858223 PMC: 10035106. DOI: 10.1177/15589447211006836.


Distal Radioulnar Joint Instability: Assessment of Three Intraoperative Radiographic Stress Tests.

Gil J, Kosinski L, Shah K, Katarincic J, Kakar S Hand (N Y). 2019; 16(5):674-678.

PMID: 31631704 PMC: 8461195. DOI: 10.1177/1558944719875487.


References
1.
Freedman D, Edwards Jr G, Willems M, Meals R . Right versus left symmetry of ulnar variance. A radiographic assessment. Clin Orthop Relat Res. 1998; (354):153-8. DOI: 10.1097/00003086-199809000-00018. View

2.
RECKLING F . Unstable fracture-dislocations of the forearm (Monteggia and Galeazzi lesions). J Bone Joint Surg Am. 1982; 64(6):857-63. View

3.
Korompilias A, Lykissas M, Kostas-Agnantis I, Beris A, Soucacos P . Distal radioulnar joint instability (Galeazzi type injury) after internal fixation in relation to the radius fracture pattern. J Hand Surg Am. 2011; 36(5):847-52. DOI: 10.1016/j.jhsa.2010.12.020. View

4.
Sanderson P, Cameron I, Holt G, Stanley D . Ulnar variance and age. J Hand Surg Br. 1997; 22(1):21-4. DOI: 10.1016/s0266-7681(97)80007-1. View

5.
Moore T, Klein J, Patzakis M, HARVEY Jr J . Results of compression-plating of closed Galeazzi fractures. J Bone Joint Surg Am. 1985; 67(7):1015-21. View