» Articles » PMID: 23970895

SIVIC: Open-Source, Standards-Based Software for DICOM MR Spectroscopy Workflows

Overview
Publisher Wiley
Specialty Radiology
Date 2013 Aug 24
PMID 23970895
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

Quantitative analysis of magnetic resonance spectroscopic imaging (MRSI) data provides maps of metabolic parameters that show promise for improving medical diagnosis and therapeutic monitoring. While anatomical images are routinely reconstructed on the scanner, formatted using the DICOM standard, and interpreted using PACS workstations, this is not the case for MRSI data. The evaluation of MRSI data is made more complex because files are typically encoded with vendor-specific file formats and there is a lack of standardized tools for reconstruction, processing, and visualization. SIVIC is a flexible open-source software framework and application suite that enables a complete scanner-to-PACS workflow for evaluation and interpretation of MRSI data. It supports conversion of vendor-specific formats into the DICOM MR spectroscopy (MRS) standard, provides modular and extensible reconstruction and analysis pipelines, and provides tools to support the unique visualization requirements associated with such data. Workflows are presented which demonstrate the routine use of SIVIC to support the acquisition, analysis, and delivery to PACS of clinical (1)H MRSI datasets at UCSF.

Citing Articles

Simultaneous noninvasive quantification of redox and downstream glycolytic fluxes reveals compartmentalized brain metabolism.

Patel S, Porcari P, Coffee E, Kim N, Berishaj M, Peyear T Sci Adv. 2024; 10(51):eadr2058.

PMID: 39705365 PMC: 11661454. DOI: 10.1126/sciadv.adr2058.


Glycaemic Response to a Nut-Enriched Diet in Asian Chinese Adults with Normal or High Glycaemia: The Tū Ora RCT.

Sequeira-Bisson I, Lu L, Silvestre M, Plank L, Middleditch N, Acevedo-Fani A Nutrients. 2024; 16(13).

PMID: 38999851 PMC: 11243085. DOI: 10.3390/nu16132103.


In vivo Hyperpolarized Metabolic Imaging to Monitor the Progression of Hepatitis B Virus (HBV)-Related Hepatitis to Liver Fibrosis.

Moon C, Heo S, Jeong Y, Lee Y, Kim S, Shin S Mol Imaging Biol. 2024; 26(4):649-657.

PMID: 38992246 DOI: 10.1007/s11307-024-01936-8.


Data Format Standardization and DICOM Integration for Hyperpolarized C MRI.

Diaz E, Sriram R, Gordon J, Sinha A, Liu X, Sahin S ArXiv. 2024; .

PMID: 38764595 PMC: 11100919.


Data Format Standardization and DICOM Integration for Hyperpolarized C MRI.

Diaz E, Sriram R, Gordon J, Sinha A, Liu X, Sahin S J Imaging Inform Med. 2024; 37(5):2627-2634.

PMID: 38710970 PMC: 11522264. DOI: 10.1007/s10278-024-01100-2.


References
1.
Crawford F, Khayal I, McGue C, Saraswathy S, Pirzkall A, Cha S . Relationship of pre-surgery metabolic and physiological MR imaging parameters to survival for patients with untreated GBM. J Neurooncol. 2008; 91(3):337-51. PMC: 3022444. DOI: 10.1007/s11060-008-9719-x. View

2.
Chang J, Thakur S, Perera G, Kowalski A, Huang W, Karimi S . Image-fusion of MR spectroscopic images for treatment planning of gliomas. Med Phys. 2006; 33(1):32-40. DOI: 10.1118/1.2128497. View

3.
Nelson S, Ozhinsky E, Li Y, Park I, Crane J . Strategies for rapid in vivo 1H and hyperpolarized 13C MR spectroscopic imaging. J Magn Reson. 2013; 229:187-97. PMC: 3808990. DOI: 10.1016/j.jmr.2013.02.003. View

4.
Tzika A . Proton magnetic resonance spectroscopic imaging as a cancer biomarker for pediatric brain tumors (Review). Int J Oncol. 2008; 32(3):517-26. DOI: 10.3892/ijo_32_3_517. View

5.
Sankar T, Caramanos Z, Assina R, Villemure J, LeBlanc R, Langleben A . Prospective serial proton MR spectroscopic assessment of response to tamoxifen for recurrent malignant glioma. J Neurooncol. 2008; 90(1):63-76. DOI: 10.1007/s11060-008-9632-3. View