» Articles » PMID: 2387943

Progressive Failure of Coronary Flow During Reperfusion of Myocardial Infarction: Documentation of the No Reflow Phenomenon with Positron Emission Tomography

Overview
Date 1990 Sep 1
PMID 2387943
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

During reperfusion of a myocardial infarct, development of microvascular occlusion may result in regional hypoperfusion ("no reflow") despite a patent infarct-related artery. This study examined the extent and time course of no reflow with use of rubidium-82 positron emission tomography. In 12 anesthetized dogs, the left anterior descending coronary artery was occluded for 90 min and then freely reperfused. Regional myocardial perfusion was imaged by serial rubidium-82 positron emission tomography during coronary occlusion and every 30 min during reperfusion. After 4 h of reperfusion, infarct size and no reflow zone were measured postmortem by triphenyltetrazolium and thioflavin staining, respectively. Perfusion defects evident on rubidium-82 images during coronary occlusion rapidly resolved during the early reflow period. However, a recurrent perfusion defect appeared after 1 to 2 h of reflow in all dogs. The severity of recurrent perfusion defects progressed with time; after 5 min of reflow, relative perfusion in the left anterior descending artery territory was 97 +/- 6% of that in the normal circumflex artery region, but perfusion decreased progressively to 68 +/- 5% after 2 h (p less than 0.05) and to 55 +/- 4% after 4 h of reperfusion (p less than 0.05 versus 2 h). As measured by radioactive tracer microspheres, endocardial blood flow decreased similarly in the postischemic left anterior descending artery region from 1.2 +/- 0.2 ml/min per g after 5 min of reflow to 0.4 +/- 0.1 ml/min per g after 3 h of reflow (p less than 0.01). Residual infarct perfusion, measured by rubidium-82 after 4 h of reflow, was related to both infarct size (r = -0.88) and the extent of the no reflow zone (r = -0.84) in the postmortem left ventricular sections. Thus, serial positron emission tomography with rubidium-82 demonstrates a progressive loss of infarct perfusion, beginning 1 to 2 h after initial restoration of blood flow despite patency of the infarct-related artery. This phenomenon is probably a manifestation of progressive microvascular occlusion within the reperfused myocardium.

Citing Articles

Association between cine CMR-based radiomics signature and microvascular obstruction in patients with ST-segment elevation myocardial infarction.

Peng Y, Wu K, Wang Y, Gong J J Thorac Dis. 2022; 14(4):969-978.

PMID: 35572892 PMC: 9096300. DOI: 10.21037/jtd-21-1706.


A Narrative Review of the Classical and Modern Diagnostic Methods of the No-Reflow Phenomenon.

Pantea-Rosan L, Bungau S, Radu A, Pantea V, Moisi M, Vesa C Diagnostics (Basel). 2022; 12(4).

PMID: 35453980 PMC: 9029120. DOI: 10.3390/diagnostics12040932.


Reperfusion Microvascular Ischemia After Prolonged Coronary Occlusion: Implications And Treatment With Local Supersaturated Oxygen Delivery.

Spears J Hypoxia (Auckl). 2019; 7:65-79.

PMID: 31696129 PMC: 6814765. DOI: 10.2147/HP.S217955.


Coronary Microembolization with Normal Epicardial Coronary Arteries and No Visible Infarcts on Nitrobluetetrazolium Chloride-Stained Specimens: Evaluation with Cardiac Magnetic Resonance Imaging in a Swine Model.

Jin H, Yun H, Ma J, Chen Z, Chang S, Zeng M Korean J Radiol. 2016; 17(1):83-92.

PMID: 26798220 PMC: 4720817. DOI: 10.3348/kjr.2016.17.1.83.


Cyclosporine A reduces microvascular obstruction and preserves left ventricular function deterioration following myocardial ischemia and reperfusion.

Zalewski J, Claus P, Bogaert J, Vanden Driessche N, Driesen R, Galan D Basic Res Cardiol. 2015; 110(2):18.

PMID: 25720581 PMC: 4342514. DOI: 10.1007/s00395-015-0475-8.