» Articles » PMID: 23873791

An Investigation into the Mechanical and Aesthetic Properties of New Generation Coated Nickel-titanium Wires in the As-received State and After Clinical Use

Overview
Journal Eur J Orthod
Specialty Dentistry
Date 2013 Jul 23
PMID 23873791
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background/objectives: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use.

Materials/methods: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires.

Results: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups.

Limitations: The extent of coating loss requires investigating, as do the biological properties of the detached coating.

Conclusions: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.

Citing Articles

Changes in Color Stability and Surface Roughness of Teflon-Coated Arch Wires After Clinical Use.

Kula B, Yilmaz B, Karaaslan E Turk J Orthod. 2023; 35(4):260-267.

PMID: 36594547 PMC: 9885819. DOI: 10.5152/TurkJOrthod.2022.20008.


Ion Release and Surface Changes of Nickel-Titanium Archwires Induced by Changes in the pH Value of the Saliva-Significance for Human Health Risk Assessment.

Jusufi Osmani Z, Poljsak B, Zelenika S, Kamenar E, Markovic K, Percic M Materials (Basel). 2022; 15(6).

PMID: 35329446 PMC: 8954586. DOI: 10.3390/ma15061994.


Evaluating the Mechanical Properties of Zinc-Coated Stainless Steel Orthodontic Wires Using Physical Vapor Deposition.

Karandish M, Pakshir M, Moghimi M, Jafarpour D Int J Dent. 2021; 2021:6651289.

PMID: 34054962 PMC: 8112955. DOI: 10.1155/2021/6651289.


Comparison of Cell Viability and Chemical Composition of Six Latest Generation Orthodontic Wires.

Escobar L, Rivera J, Arbelaez E, Torres L, Villafane A, Diaz-Baez D Int J Biomater. 2021; 2021:8885290.

PMID: 33574848 PMC: 7861923. DOI: 10.1155/2021/8885290.


Attractiveness of different esthetic orthodontic wires.

Batista D, Faccini M, Valarelli F, Hermont Cancado R, Oliveira R, de Oliveira R Dental Press J Orthod. 2021; 25(6):27-32.

PMID: 33503122 PMC: 7869809. DOI: 10.1590/2177-6709.25.6.027-032.oar.