» Articles » PMID: 23856983

Intravitreal Silicone Oil Induced Changes in Corneal Biomechanics

Overview
Journal Int Ophthalmol
Specialty Ophthalmology
Date 2013 Jul 17
PMID 23856983
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Our aim was to detect the early effects of pars plana vitrectomy (PPV) combined with intravitreal silicone oil (SO) on corneal biomechanics. 19 eyes underwent PPV with SO tamponade (group 1) and 16 eyes underwent. PPV without tamponade (group 2). Corneal biomechanical parameters were measured preoperatively and at the first postoperative month by ocular response analyzer. The mean preoperative intraocular pressure (IOP) by Goldmann applanation tonometry (GAT) and the mean corneal-compensated intraocular pressure (IOPcc) were significantly lower in group 1 than group 2 (p = 0.005, p = 0.002, respectively). The mean preoperative corneal hysteresis (CH) and corneal resistance factor (CRF) were significantly higher in group 1 than group 2 (p = 0.017, p = 0.002, respectively). However, the difference in Goldmann-correlated intraocular pressure (IOPg) between the groups was not significant (p = 0.360). In group 1, IOPcc, IOPg and IOP-GAT significantly increased postoperatively (p = 0.002, p = 0.004, p = 0.002, respectively) but CH and CRF decreased (p = 0.007, p = 0.153, respectively). In group 2, IOPcc, IOPg and IOP (GAT) increased postoperatively but the differences were not significant (p = 0.851, p = 0.693, p = 0.336, respectively). The mean CRF increased significantly (p = 0.026) postoperatively but the decrease in CH was not significant (p = 0.196). Statistically significant differences were found in the changes of preoperative and postoperative means of IOPcc, IOPg, IOP-GAT and CRF between the groups (p = 0.024, p = 0.037, p = 0.014, p = 0.006, respectively). However, the difference in the decreases in CH between the two groups was not statistically significant (p = 0.206). SO tamponade may affect corneal biomechanical parameters in the early postoperative period, which may be related to the surgery itself, SO tamponade or IOP changes.

Citing Articles

Emulsification of Silicone Oils: Altering Factors and Possible Complications-A Narrative Review.

Latkowska M, Gajdzis M, Kaczmarek R J Clin Med. 2024; 13(8).

PMID: 38673681 PMC: 11051299. DOI: 10.3390/jcm13082407.


Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement.

Pniakowska Z, Jurowski P Sci Rep. 2023; 13(1):154.

PMID: 36599896 PMC: 9813351. DOI: 10.1038/s41598-023-27407-8.


Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade.

Ferrara M, Coco G, Sorrentino T, Jasani K, Moussa G, Morescalchi F J Clin Med. 2022; 11(17).

PMID: 36079165 PMC: 9457190. DOI: 10.3390/jcm11175234.


A pilot study of the precision of digital intraocular pressure measurement during vitrectomy.

Xue C, Li S, Miao J, Wu S, Tian X, Zhang C Int J Ophthalmol. 2020; 13(10):1574-1579.

PMID: 33078107 PMC: 7511381. DOI: 10.18240/ijo.2020.10.10.


The relationship between inflammatory mediator expression in the aqueous humor and secondary glaucoma incidence after silicone oil tamponade.

Liu Z, Fu G, Liu A Exp Ther Med. 2017; 14(6):5833-5836.

PMID: 29285128 PMC: 5740688. DOI: 10.3892/etm.2017.5269.


References
1.
Kobuch K, Menz I, Hoerauf H, Dresp J, Gabel V . New substances for intraocular tamponades: perfluorocarbon liquids, hydrofluorocarbon liquids and hydrofluorocarbon-oligomers in vitreoretinal surgery. Graefes Arch Clin Exp Ophthalmol. 2001; 239(9):635-42. DOI: 10.1007/s004170100330. View

2.
ElMallah M, Asrani S . New ways to measure intraocular pressure. Curr Opin Ophthalmol. 2008; 19(2):122-6. DOI: 10.1097/ICU.0b013e3282f391ae. View

3.
Szaflik J, Kmera-Muszynska M . Confocal microscopy imaging of the cornea in patients with silicone oil in the anterior chamber after vitreoretinal surgery. Graefes Arch Clin Exp Ophthalmol. 2006; 245(2):210-4. DOI: 10.1007/s00417-006-0433-0. View

4.
CIBIS P, Becker B, Okun E, Canaan S . The use of liquid silicone in retinal detachment surgery. Arch Ophthalmol. 1962; 68:590-9. DOI: 10.1001/archopht.1962.00960030594005. View

5.
Romano M, Angi M, Romano V, Parmeggiani F, Campa C, Valldeperas X . Intraocular pressure changes following the use of silicone oil or Densiron 68 as endotamponade in pars plana vitrectomy. Clin Ophthalmol. 2010; 4:1391-6. PMC: 2999554. DOI: 10.2147/OPTH.S14252. View