Abstract

Ceramic bearing surfaces are increasingly used for total hip replacement, notwithstanding that concern is still related to ceramic brittleness and its possible mechanical failure. The aim of this systematic review is to answer three questions: (1) Are there risk factors for ceramic component fracture following total hip replacement? (2) Is it possible to perform an early diagnosis of ceramic component failure before catastrophic fracture occurs? (3) Is it possible to draw guidelines for revision surgery after ceramic components failure? A PubMed and Google Scholar search was performed and reference citations from publications identified in the literature search were reviewed. The use of 28 mm short-neck femoral head carries an increased risk of fracture. Acetabular component malposition might increase the risk of ceramic liner fractures. Synovial fluid microanalysis and CT scan are promising in early diagnosis of ceramic head and liner failure. Early revision is suggested in case of component failure; no consensus exists about the better coupling for revision surgery. Ceramic brittleness remains a major concern. Due to the increased number of ceramic on ceramic implants, more revision surgeries and reports on ceramic components failure are expected in the future. An algorithm of diagnosis and treatment for ceramic hip failure is proposed.

Citing Articles

Fourth-generation Ceramic Head Fracture in Total Hip Arthroplasty: A Case Report and Literature Review.

Yin C, Eberhardt L, Cederman M, Haley H, Steffenmeier A, Karadsheh M Arthroplast Today. 2025; 32:101614.

PMID: 40026482 PMC: 11869593. DOI: 10.1016/j.artd.2025.101614.


Material-Intrinsic NIR-Fluorescence Enables Image-Guided Surgery for Ceramic Fracture Removal.

Nissler R, Totter E, Walter S, Metternich J, Cipolato O, Nowack D Adv Healthc Mater. 2024; 13(10):e2302950.

PMID: 38245823 PMC: 11481054. DOI: 10.1002/adhm.202302950.


Evaluating the Feasibility and Reproducibility of a Novel Insertion Method for Modular Acetabular Ceramic Liners.

Hunger S, Seidler A, Rotsch C, Heyde C, Drossel W Bioengineering (Basel). 2023; 10(10).

PMID: 37892910 PMC: 10604853. DOI: 10.3390/bioengineering10101180.


Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces.

Godoy M, Sipek K, Gustafson J, Yuh C, Levine B, Pourzal R J Arthroplasty. 2023; 39(2):507-513.e1.

PMID: 37598779 PMC: 10850914. DOI: 10.1016/j.arth.2023.08.049.


Late Atraumatic Ceramic Head Fracture in Total Hip Arthroplasty: A Case Report.

Hungerford M, Neubauer P, Boner A, Kowalewski A J Orthop Case Rep. 2023; 13(6):65-68.

PMID: 37398526 PMC: 10308988. DOI: 10.13107/jocr.2023.v13.i06.3698.


References
1.
Habermann B, Ewald W, Rauschmann M, Zichner L, Kurth A . Fracture of ceramic heads in total hip replacement. Arch Orthop Trauma Surg. 2006; 126(7):464-70. DOI: 10.1007/s00402-006-0173-y. View

2.
Dunstan E, Ladon D, Whittingham-Jones P, Carrington R, Briggs T . Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings. J Bone Joint Surg Am. 2008; 90(3):517-22. DOI: 10.2106/JBJS.F.01435. View

3.
Koo K, Ha Y, Jung W, Kim S, Yoo J, Kim H . Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am. 2008; 90(2):329-36. DOI: 10.2106/JBJS.F.01489. View

4.
Nizard R, Sedel L, Christel P, Meunier A, Soudry M, Witvoet J . Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop Relat Res. 1992; (282):53-63. View

5.
Yoo J, Kim Y, Yoon K, Koo K, Song W, Kim H . Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am. 2005; 87(3):530-5. DOI: 10.2106/JBJS.D.01753. View