» Articles » PMID: 23809675

Planning of Anatomical Liver Segmentectomy and Subsegmentectomy with 3-dimensional Simulation Software

Overview
Journal Am J Surg
Specialty General Surgery
Date 2013 Jul 2
PMID 23809675
Citations 45
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The aim of this study was to evaluate whether 3-dimensional (3D) simulation software is applicable to and useful for anatomic liver segmentectomy and subsegmentectomy.

Methods: A prospective study of 83 consecutive patients who underwent anatomic segmentectomy or subsegmentectomy using the puncture method was performed. All patients underwent 3D simulation analysis (SA) preoperatively for planning operative procedures. The clinical information acquired by 3D SA and the consistency of virtual and real hepatectomy were evaluated.

Results: The time needed for completing 3D SA was 18.3 ± .7 minutes. Three-dimensional SA proposed resection of multiple segments or subsegments in 29 patients (35%). It also helped complement the resection line in 26 patients (31%) who lacked a bold staining area on the liver surface. The volume of segment or subsegment calculated by 3D SA was correlated with the actual resected specimen (R(2) = .9942, P < .01). The bordering hepatic veins were clearly exposed in 71 patients (86%), in accordance with completed drawings by 3D SA.

Conclusions: Three-dimensional SA showed accurate completed drawings and assisted liver surgeons in planning and executing anatomic segmentectomy and subsegmentectomy.

Citing Articles

Surgical treatment for hepatocellular carcinoma in era of multidisciplinary strategies.

Takamoto T, Mihara Y, Nishioka Y, Ichida A, Kawaguchi Y, Akamatsu N Int J Clin Oncol. 2025; 30(3):417-426.

PMID: 39907863 PMC: 11842484. DOI: 10.1007/s10147-025-02703-7.


Practical Step-by-step SYNAPSE VINCENT Rendering of Three-dimensional Graphics in Horseshoe Kidney with Bilateral Varicoceles.

Kojo K, Kim J, Saida T, Ohta T, Sano K, Kandori S JMA J. 2024; 7(4):471-486.

PMID: 39513055 PMC: 11543326. DOI: 10.31662/jmaj.2024-0058.


Reproducibility and efficiency of liver volumetry using manual method and liver analysis software.

Maki H, Nishioka Y, Haddad A, Lendoire M, Tran Cao H, Chun Y HPB (Oxford). 2024; 26(7):911-918.

PMID: 38632032 PMC: 11753197. DOI: 10.1016/j.hpb.2024.03.1157.


Intraoperative artificial intelligence system identifying liver vessels in laparoscopic liver resection: a retrospective experimental study.

Une N, Kobayashi S, Kitaguchi D, Sunakawa T, Sasaki K, Ogane T Surg Endosc. 2024; 38(2):1088-1095.

PMID: 38216749 DOI: 10.1007/s00464-023-10637-2.


Evaluation and Prediction of Post-Hepatectomy Liver Failure Using Imaging Techniques: Value of Gadoxetic Acid-Enhanced Magnetic Resonance Imaging.

Sofue K, Shimada R, Ueshima E, Komatsu S, Yamaguchi T, Yabe S Korean J Radiol. 2024; 25(1):24-32.

PMID: 38184766 PMC: 10788604. DOI: 10.3348/kjr.2023.0507.