Background: Moving from sitting to standing is a common activity of daily living. The five-repetition sit-to-stand test (5STS) is a test of lower limb function that measures the fastest time taken to stand five times from a chair with arms folded. The 5STS has been validated in healthy community-dwelling adults, but data in chronic obstructive pulmonary disease (COPD) populations are lacking.

Aims: To determine the reliability, validity and responsiveness of the 5STS in patients with COPD.

Methods: Test-retest and interobserver reliability of the 5STS was measured in 50 patients with COPD. To address construct validity we collected data on the 5STS, exercise capacity (incremental shuttle walk (ISW)), lower limb strength (quadriceps maximum voluntary contraction (QMVC)), health status (St George's Respiratory Questionnaire (SGRQ)) and composite mortality indices (Age Dyspnoea Obstruction index (ADO), BODE index (iBODE)). Responsiveness was determined by measuring 5STS before and after outpatient pulmonary rehabilitation (PR) in 239 patients. Minimum clinically important difference (MCID) was estimated using anchor-based methods.

Results: Test-retest and interobserver intraclass correlation coefficients were 0.97 and 0.99, respectively. 5STS time correlated significantly with ISW, QMVC, SGRQ, ADO and iBODE (r=-0.59, -0.38, 0.35, 0.42 and 0.46, respectively; all p<0.001). Median (25th, 75th centiles) 5STS time decreased with PR (Pre: 14.1 (11.5, 21.3) vs Post: 12.4 (10.2, 16.3) s; p<0.001). Using different anchors, a conservative estimate for the MCID was 1.7 s.

Conclusions: The 5STS is reliable, valid and responsive in patients with COPD with an estimated MCID of 1.7 s. It is a practical functional outcome measure suitable for use in most healthcare settings.

Citing Articles

Correlation of Sit-to-Stand Test and 6-Minute Walk Test to Illustrate Cardiorespiratory Fitness in Systolic Heart Failure Patients.

Triangto I, Dhamayanti A, Putra M, Witjaksono D, Rahmad , Zuhriyah L Ann Rehabil Med. 2025; 49(1):23-29.

PMID: 40033954 PMC: 11895058. DOI: 10.5535/arm.240057.


Shear wave elastography, as a feasible tool, can be used to reflect the lower limb dysfunction in patients with chronic obstructive pulmonary disease?.

Yue Y, Niu Y, Tang W, Li S, Xu L, Chen Z Sci Rep. 2025; 15(1):6532.

PMID: 39994283 PMC: 11850852. DOI: 10.1038/s41598-025-91082-0.


The influence of sex on activity in voluntary wheel running, forced treadmill running, and open field testing in mice.

Janowski A, Berardi G, Hayashi K, Plumb A, Lesnak J, Khataei T Physiol Rep. 2025; 13(4):e70246.

PMID: 39985141 PMC: 11845322. DOI: 10.14814/phy2.70246.


Virtual recovery: efficacy of telerehabilitation on dyspnea, pain, and functional capacity in post-COVID-19 syndrome.

Yasaci Z, Mustafaoglu R, Ozgur O, Kuveloglu B, Esen Y, Ozmen O Ir J Med Sci. 2025; .

PMID: 39920519 DOI: 10.1007/s11845-025-03899-3.


Assessing a clinical vital sign in severe mental illness: validation study of the 5 sit-to-stand test for monitoring muscle strength - The PsychiActive Project.

Lopez-Moral A, Munguia-Izquierdo D, Bueno-Antequera J BJPsych Open. 2025; 11(1):e24.

PMID: 39866000 PMC: 11823003. DOI: 10.1192/bjo.2024.842.