» Articles » PMID: 23781129

Comprehensive Evaluation of Biological Growth Control by Chlorine-Based Biocides in Power Plant Cooling Systems Using Tertiary Effluent

Overview
Journal Environ Eng Sci
Date 2013 Jun 20
PMID 23781129
Authors
Affiliations
Soon will be listed here.
Abstract

Recent studies have shown that treated municipal wastewater can be a reliable cooling water alternative to fresh water. However, elevated nutrient concentration and microbial population in wastewater lead to aggressive biological proliferation in the cooling system. Three chlorine-based biocides were evaluated for the control of biological growth in cooling systems using tertiary treated wastewater as makeup, based on their biocidal efficiency and cost-effectiveness. Optimal chemical regimens for achieving successful biological growth control were elucidated based on batch-, bench-, and pilot-scale experiments. Biocide usage and biological activity in planktonic and sessile phases were carefully monitored to understand biological growth potential and biocidal efficiency of the three disinfectants in this particular environment. Water parameters, such as temperature, cycles of concentration, and ammonia concentration in recirculating water, critically affected the biocide performance in recirculating cooling systems. Bench-scale recirculating tests were shown to adequately predict the biocide residual required for a pilot-scale cooling system. Optimal residuals needed for proper biological growth control were 1, 2-3, and 0.5-1 mg/L as Cl for NaOCl, preformed NHCl, and ClO, respectively. Pilot-scale tests also revealed that was absent from these cooling systems when using the disinfectants evaluated in this study. Cost analysis showed that NaOCl is the most cost-effective for controlling biological growth in power plant recirculating cooling systems using tertiary-treated wastewater as makeup.

References
1.
Li H, Chien S, Hsieh M, Dzombak D, Vidic R . Escalating water demand for energy production and the potential for use of treated municipal wastewater. Environ Sci Technol. 2011; 45(10):4195-200. DOI: 10.1021/es1040305. View

2.
Chien S, Hsieh M, Li H, Monnell J, Dzombak D, Vidic R . Pilot-scale cooling tower to evaluate corrosion, scaling, and biofouling control strategies for cooling system makeup water. Rev Sci Instrum. 2012; 83(2):024101. DOI: 10.1063/1.3680563. View

3.
Kim B, Anderson J, Mueller S, Gaines W, Kendall A . Literature review--efficacy of various disinfectants against Legionella in water systems. Water Res. 2002; 36(18):4433-44. DOI: 10.1016/s0043-1354(02)00188-4. View

4.
Fraser D, Tsai T, Orenstein W, Parkin W, Beecham H, Sharrar R . Legionnaires' disease: description of an epidemic of pneumonia. N Engl J Med. 1977; 297(22):1189-97. DOI: 10.1056/NEJM197712012972201. View

5.
Costerton J, Stewart P, Greenberg E . Bacterial biofilms: a common cause of persistent infections. Science. 1999; 284(5418):1318-22. DOI: 10.1126/science.284.5418.1318. View