» Articles » PMID: 23754253

First-trimester Screening for Early and Late Small-for-gestational-age Neonates Using Maternal Serum Biochemistry, Blood Pressure and Uterine Artery Doppler

Overview
Date 2013 Jun 12
PMID 23754253
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To assess the effectiveness of first-trimester screening for early and late small-for-gestational-age (SGA) neonates using maternal serum biochemistry, blood pressure and uterine artery Doppler.

Methods: This was a prospective study of 4970 women with a singleton pregnancy who underwent routine first-trimester screening between 2009 and 2011. A logistic regression-based predictive model for SGA, defined as birth weight < 10(th) percentile, divided into early- or late-onset based on gestational age at delivery before or after 34 weeks' gestation, was constructed. The model included maternal baseline characteristics: serum levels of pregnancy-associated plasma protein-A and free β-human chorionic gonadotropin at 8-12 weeks and blood pressure and uterine artery Doppler at 11 + 0 to 13 + 6 weeks.

Results: The prevalence of early and late SGA was 0.6% and 7.9%, respectively. Association with pre-eclampsia was 67% and 8%, respectively. At a false-positive rate of 15%, the detection rate for early SGA was 73%; however it differed substantially for cases with and without pre-eclampsia (90% vs 40%). For late SGA, at false-positive rates of 15 and 50%, detection rates were 32% and 70%, respectively, and did not substantially differ between cases with and without pre-eclampsia.

Conclusions: First-trimester screening predicts early SGA mainly because of its strong association with pre-eclampsia. Although prediction of late SGA was poorer, at a high false-positive rate it might be considered as part of a first-trimester strategy to select women requiring ultrasound assessment in the third trimester.

Citing Articles

Maternal Uterine Artery Doppler and Serum Marker in the First Trimester as Predictive Markers for Small for Gestational Age Neonates and Preeclampsia: A Pilot Study.

Lee J, Lee K, Park S, Kim S, Shim S, Kim Y Diagnostics (Basel). 2025; 15(2).

PMID: 39857117 PMC: 11764443. DOI: 10.3390/diagnostics15020233.


Maternal Serum Angiogenic Profile and Its Correlations with Ultrasound Parameters and Perinatal Results in Normotensive and Preeclamptic Pregnancies Complicated by Fetal Growth Restriction.

Dymara-Konopka W, Laskowska M, Grywalska E, Hymos A, Leszczynska-Gorzelak B J Clin Med. 2023; 12(13).

PMID: 37445317 PMC: 10342798. DOI: 10.3390/jcm12134281.


Prediction Models for Intrauterine Growth Restriction Using Artificial Intelligence and Machine Learning: A Systematic Review and Meta-Analysis.

Rescinito R, Ratti M, Payedimarri A, Panella M Healthcare (Basel). 2023; 11(11).

PMID: 37297757 PMC: 10252230. DOI: 10.3390/healthcare11111617.


Correlation of Fetal Heart Rate, Uterine Artery Pulsatility Index, Pregnancy Associated Plasma Protein-A and Crown-Rump Length in Pre-eclampsia - a Prospective Cohort Study.

Hantoushzadeh S, Ahangari R, Balaneji S, Ghamari A, Hashemnejad M, Piri S Maedica (Bucur). 2023; 18(1):50-54.

PMID: 37266467 PMC: 10231157. DOI: 10.26574/maedica.2023.18.1.50.


OPtimal TIming of antenatal COrticosteroid administration in pregnancies complicated by early-onset fetal growth REstriction (OPTICORE): study protocol of a multicentre, retrospective cohort study.

van de Meent M, Kleuskens D, Ganzevoort W, Gordijn S, Kooi E, Onland W BMJ Open. 2023; 13(3):e070729.

PMID: 36931680 PMC: 10030622. DOI: 10.1136/bmjopen-2022-070729.