» Articles » PMID: 23732690

An Optimised Patient-specific Approach to Administration of Contrast Agent for CT Pulmonary Angiography

Overview
Journal Eur Radiol
Specialty Radiology
Date 2013 Jun 5
PMID 23732690
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To investigate pulmonary vasculature opacification during CTPA using an optimised patient-specific protocol for administering contrast agent.

Methods: CTPA was performed on 200 patients with suspected PE. Patients were assigned to two protocol groups: protocol A, fixed 80 ml contrast agent; protocol B used a patient-specific approach. The mean cross-sectional opacification profile of 8 central and 11 peripheral pulmonary arteries and veins was measured and the arteriovenous contrast ratio (AVCR) calculated. Protocols were compared using Mann-Whitney U non-parametric statistics. Jack-knife alternative free-response receiver-operating characteristic (JAFROC) analyses assessed diagnostic efficacy. Interobserver variations were investigated using kappa methods.

Results: A number of pulmonary arteries demonstrated increases in opacification (P < 0.03) for protocol B compared to A, whilst opacification in the heart and veins was reduced in protocol B (P = 0.05). Increased AVCR in protocol B compared with A was observed at all anatomic locations (P < 0.0002). Increased JAFROC (P < 0.0002) and kappa variation were observed with protocol B (κ = 0.78) compared to A (κ = 0.25). Mean contrast volume was reduced in protocol B (33 ± 9 ml) compared to A (80 ± 1 ml).

Conclusions: Significant improvements in visualisation of the pulmonary vasculature can be achieved with a low volume of contrast agent using injection timing based on a patient-specific contrast formula.

Key Points: • Optimal opacification of the pulmonary arteries is essential for CT pulmonary angiography. • Matching timing with vessel dynamics significantly improves vessel opacification. • This leads to increased arterial opacification and reduced venous opacification. • This can also lead to a reduced volume of contrast agent.

Citing Articles

The Diverse Utility of Contrast Media Delivery and Dosing During Computed Tomography: An International Assessment of Knowledge and Practices.

Rawashdeh M, Kashabash D, Kumar P, Saade C Curr Radiopharm. 2024; 17(4):364-370.

PMID: 38571349 DOI: 10.2174/0118744710293946240325051232.


Minimizing contrast media dose in CT pulmonary angiography with high-pitch technique.

Alobeidi H, Alshamari M, Widell J, Eriksson T, Liden M Br J Radiol. 2020; 93(1111):20190995.

PMID: 32436788 PMC: 7336071. DOI: 10.1259/bjr.20190995.


CT angiography for pulmonary embolism in the emergency department: investigation of a protocol by 20 ml of high-concentration contrast medium.

Silva M, Milanese G, Cobelli R, Manna C, Rasciti E, Poggesi S Radiol Med. 2019; 125(2):137-144.

PMID: 31659676 DOI: 10.1007/s11547-019-01098-6.


Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Rajiah P, Ciancibello L, Novak R, Sposato J, Landeras L, Gilkeson R Diagn Interv Radiol. 2019; 25(3):195-203.

PMID: 31063136 PMC: 6521906. DOI: 10.5152/dir.2019.17498.


Synchronisation between contrast media administration and caudocranial scan direction increases visualisation of altered coronary artery blood flow in patients presenting with dual left anterior descending coronary artery.

Saade C, El-Merhi F, El-Ashkar B, Mohamad M, Haydar A, Abchee A BJR Case Rep. 2018; 3(2):20150500.

PMID: 30363277 PMC: 6159239. DOI: 10.1259/bjrcr.20150500.


References
1.
Tillie-Leblond I, Mastora I, Radenne F, Paillard S, Tonnel A, Remy J . Risk of pulmonary embolism after a negative spiral CT angiogram in patients with pulmonary disease: 1-year clinical follow-up study. Radiology. 2002; 223(2):461-7. DOI: 10.1148/radiol.2232010913. View

2.
Hittmair K, Fleischmann D . Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection. J Comput Assist Tomogr. 2001; 25(2):287-94. DOI: 10.1097/00004728-200103000-00024. View

3.
Batra P, Bigoni B, Manning J, Aberle D, Brown K, Hart E . Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography. Radiographics. 2000; 20(2):309-20. DOI: 10.1148/radiographics.20.2.g00mc04309. View

4.
Ghaye B, Szapiro D, Mastora I, Delannoy V, Duhamel A, Remy J . Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis?. Radiology. 2001; 219(3):629-36. DOI: 10.1148/radiology.219.3.r01jn32629. View

5.
Raptopoulos V, Boiselle P . Multi-detector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT. Radiology. 2001; 221(3):606-13. DOI: 10.1148/radiol.2213010473. View