An Optimised Patient-specific Approach to Administration of Contrast Agent for CT Pulmonary Angiography
Overview
Affiliations
Objectives: To investigate pulmonary vasculature opacification during CTPA using an optimised patient-specific protocol for administering contrast agent.
Methods: CTPA was performed on 200 patients with suspected PE. Patients were assigned to two protocol groups: protocol A, fixed 80 ml contrast agent; protocol B used a patient-specific approach. The mean cross-sectional opacification profile of 8 central and 11 peripheral pulmonary arteries and veins was measured and the arteriovenous contrast ratio (AVCR) calculated. Protocols were compared using Mann-Whitney U non-parametric statistics. Jack-knife alternative free-response receiver-operating characteristic (JAFROC) analyses assessed diagnostic efficacy. Interobserver variations were investigated using kappa methods.
Results: A number of pulmonary arteries demonstrated increases in opacification (P < 0.03) for protocol B compared to A, whilst opacification in the heart and veins was reduced in protocol B (P = 0.05). Increased AVCR in protocol B compared with A was observed at all anatomic locations (P < 0.0002). Increased JAFROC (P < 0.0002) and kappa variation were observed with protocol B (κ = 0.78) compared to A (κ = 0.25). Mean contrast volume was reduced in protocol B (33 ± 9 ml) compared to A (80 ± 1 ml).
Conclusions: Significant improvements in visualisation of the pulmonary vasculature can be achieved with a low volume of contrast agent using injection timing based on a patient-specific contrast formula.
Key Points: • Optimal opacification of the pulmonary arteries is essential for CT pulmonary angiography. • Matching timing with vessel dynamics significantly improves vessel opacification. • This leads to increased arterial opacification and reduced venous opacification. • This can also lead to a reduced volume of contrast agent.
Rawashdeh M, Kashabash D, Kumar P, Saade C Curr Radiopharm. 2024; 17(4):364-370.
PMID: 38571349 DOI: 10.2174/0118744710293946240325051232.
Minimizing contrast media dose in CT pulmonary angiography with high-pitch technique.
Alobeidi H, Alshamari M, Widell J, Eriksson T, Liden M Br J Radiol. 2020; 93(1111):20190995.
PMID: 32436788 PMC: 7336071. DOI: 10.1259/bjr.20190995.
Silva M, Milanese G, Cobelli R, Manna C, Rasciti E, Poggesi S Radiol Med. 2019; 125(2):137-144.
PMID: 31659676 DOI: 10.1007/s11547-019-01098-6.
Rajiah P, Ciancibello L, Novak R, Sposato J, Landeras L, Gilkeson R Diagn Interv Radiol. 2019; 25(3):195-203.
PMID: 31063136 PMC: 6521906. DOI: 10.5152/dir.2019.17498.
Saade C, El-Merhi F, El-Ashkar B, Mohamad M, Haydar A, Abchee A BJR Case Rep. 2018; 3(2):20150500.
PMID: 30363277 PMC: 6159239. DOI: 10.1259/bjrcr.20150500.