» Articles » PMID: 23642047

Oxygen Saturation and Outcomes in Preterm Infants

Abstract

Background: The clinically appropriate range for oxygen saturation in preterm infants is unknown. Previous studies have shown that infants had reduced rates of retinopathy of prematurity when lower targets of oxygen saturation were used.

Methods: In three international randomized, controlled trials, we evaluated the effects of targeting an oxygen saturation of 85 to 89%, as compared with a range of 91 to 95%, on disability-free survival at 2 years in infants born before 28 weeks' gestation. Halfway through the trials, the oximeter-calibration algorithm was revised. Recruitment was stopped early when an interim analysis showed an increased rate of death at 36 weeks in the group with a lower oxygen saturation. We analyzed pooled data from patients and now report hospital-discharge outcomes.

Results: A total of 2448 infants were recruited. Among the 1187 infants whose treatment used the revised oximeter-calibration algorithm, the rate of death was significantly higher in the lower-target group than in the higher-target group (23.1% vs. 15.9%; relative risk in the lower-target group, 1.45; 95% confidence interval [CI], 1.15 to 1.84; P=0.002). There was heterogeneity for mortality between the original algorithm and the revised algorithm (P=0.006) but not for other outcomes. In all 2448 infants, those in the lower-target group for oxygen saturation had a reduced rate of retinopathy of prematurity (10.6% vs. 13.5%; relative risk, 0.79; 95% CI, 0.63 to 1.00; P=0.045) and an increased rate of necrotizing enterocolitis (10.4% vs. 8.0%; relative risk, 1.31; 95% CI, 1.02 to 1.68; P=0.04). There were no significant between-group differences in rates of other outcomes or adverse events.

Conclusions: Targeting an oxygen saturation below 90% with the use of current oximeters in extremely preterm infants was associated with an increased risk of death. (Funded by the Australian National Health and Medical Research Council and others; BOOST II Current Controlled Trials number, ISRCTN00842661, and Australian New Zealand Clinical Trials Registry numbers, ACTRN12605000055606 and ACTRN12605000253606.).

Citing Articles

Statistical analysis plan for the FiO-C trial: effects of closed-loop automatic control of the inspiratory fraction of oxygen (FiO-C) on outcomes of extremely preterm infants-a randomized-controlled parallel group multicentre trial for safety and....

Konig J, Stauch A, Engel C, Urschitz M, Franz A Trials. 2024; 25(1):756.

PMID: 39533330 PMC: 11559155. DOI: 10.1186/s13063-024-08615-7.


Impact of early continuous positive airway pressure in the delivery room (DR-CPAP) on neonates < 1500 g in a low-resource setting: a protocol for a pilot feasibility and acceptability randomized controlled trial.

Burgoine K, Ssenkusu J, Nakiyemba A, Okello F, Napyo A, Hagmann C Pilot Feasibility Stud. 2024; 10(1):126.

PMID: 39367449 PMC: 11451038. DOI: 10.1186/s40814-024-01552-x.


Closed-loop oxygen usage during invasive mechanical ventilation of pediatric patients (CLOUDIMPP): a randomized controlled cross-over study.

Atakul G, Ceylan G, Sandal O, Soydan E, Hepduman P, Colak M Front Med (Lausanne). 2024; 11:1426969.

PMID: 39318593 PMC: 11420134. DOI: 10.3389/fmed.2024.1426969.


[Focus on ventilation, oxygen therapy and weaning 2022-2024 : Summary of selected intensive care studies].

Fiedler-Kalenka M, Brenner T, Bernhard M, Reuss C, Beynon C, Hecker A Anaesthesiologie. 2024; 73(10):698-711.

PMID: 39210065 DOI: 10.1007/s00101-024-01455-9.


Bioinformatic analysis reveals the relationship between macrophage infiltration and Cybb downregulation in hyperoxia-induced bronchopulmonary dysplasia.

He Y, Li D, Zhang M, Li F Sci Rep. 2024; 14(1):20089.

PMID: 39209930 PMC: 11362550. DOI: 10.1038/s41598-024-70877-7.