» Articles » PMID: 23621946

Mammogram Image Quality As a Potential Contributor to Disparities in Breast Cancer Stage at Diagnosis: an Observational Study

Overview
Journal BMC Cancer
Publisher Biomed Central
Specialty Oncology
Date 2013 Apr 30
PMID 23621946
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Background: In an ongoing study of racial/ethnic disparities in breast cancer stage at diagnosis, we consented patients to allow us to review their mammogram images, in order to examine the potential role of mammogram image quality on this disparity.

Methods: In a population-based study of urban breast cancer patients, a single breast imaging specialist (EC) performed a blinded review of the index mammogram that prompted diagnostic follow-up, as well as recent prior mammograms performed approximately one or two years prior to the index mammogram. Seven indicators of image quality were assessed on a five-point Likert scale, where 4 and 5 represented good and excellent quality. These included 3 technologist-associated image quality (TAIQ) indicators (positioning, compression, sharpness), and 4 machine associated image quality (MAIQ) indicators (contrast, exposure, noise and artifacts). Results are based on 494 images examined for 268 patients, including 225 prior images.

Results: Whereas MAIQ was generally high, TAIQ was more variable. In multivariable models of sociodemographic predictors of TAIQ, less income was associated with lower TAIQ (p < 0.05). Among prior mammograms, lower TAIQ was subsequently associated with later stage at diagnosis, even after adjusting for multiple patient and practice factors (OR = 0.80, 95% CI: 0.65, 0.99).

Conclusions: Considerable gains could be made in terms of increasing image quality through better positioning, compression and sharpness, gains that could impact subsequent stage at diagnosis.

Citing Articles

Acquisition parameters influence AI recognition of race in chest x-rays and mitigating these factors reduces underdiagnosis bias.

Lotter W Nat Commun. 2024; 15(1):7465.

PMID: 39198519 PMC: 11358468. DOI: 10.1038/s41467-024-52003-3.


Digital breast tomosynthesis in mammographic screening: false negative cancer cases in the To-Be 1 trial.

Moshina N, Grawingholt A, Lang K, Mann R, Hovda T, Roth Hoff S Insights Imaging. 2024; 15(1):38.

PMID: 38332187 PMC: 10853101. DOI: 10.1186/s13244-023-01604-5.


Quality assurance in Mammography: An overview.

Feigin K Eur J Radiol. 2023; 165:110935.

PMID: 37354771 PMC: 10528604. DOI: 10.1016/j.ejrad.2023.110935.


Intra- and inter-rater reliability of compressed breast thickness, applied force, and pressure distribution in screening mammography.

Voigt M, Bolejko A, Dustler M Acta Radiol Open. 2022; 10(12):20584601211062078.

PMID: 35140983 PMC: 8819760. DOI: 10.1177/20584601211062078.


A review of mammographic image quality in Papua New Guinea.

Pape R, Spuur K, Wilkinson J, Zuhukepe A J Med Radiat Sci. 2021; 69(1):24-29.

PMID: 34418330 PMC: 8892422. DOI: 10.1002/jmrs.538.


References
1.
Destouet J, Bassett L, Yaffe M, Butler P, Wilcox P . The ACR's Mammography Accreditation Program: ten years of experience since MQSA. J Am Coll Radiol. 2007; 2(7):585-94. DOI: 10.1016/j.jacr.2004.12.005. View

2.
Woloshin S, Schwartz L . The benefits and harms of mammography screening: understanding the trade-offs. JAMA. 2010; 303(2):164-5. DOI: 10.1001/jama.2009.2007. View

3.
. Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2009; 151(10):716-26, W-236. DOI: 10.7326/0003-4819-151-10-200911170-00008. View

4.
Rauscher G, Allgood K, Whitman S, Conant E . Disparities in screening mammography services by race/ethnicity and health insurance. J Womens Health (Larchmt). 2011; 21(2):154-60. PMC: 3270049. DOI: 10.1089/jwh.2010.2415. View

5.
Nelson H, Tyne K, Naik A, Bougatsos C, Chan B, Humphrey L . Screening for breast cancer: an update for the U.S. Preventive Services Task Force. Ann Intern Med. 2009; 151(10):727-37, W237-42. PMC: 2972726. DOI: 10.7326/0003-4819-151-10-200911170-00009. View