High-pitch, Dual-source Chest Computed Tomography Angiography Without Electrocardiographic Synchronization: Evaluation of Cardiac Motion Artifacts on Pulmonary Circulation

Overview
Date 2013 Apr 26
PMID 23615574
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate the frequency and severity of cardiac motion artifacts on high-pitch, dual-source computed tomography angiograms of the chest.

Materials And Methods: One hundred consecutive patients underwent a non-electrocardiogram-gated, dual-source chest computed tomography examination with high pitch and high temporal resolution.

Results: The mean (±SD) duration of data acquisition was 0.9 (±0.07) seconds and the mean (±SD) heart rate was 78.9 (±15.2) bpm. Cardiac motion artifacts were seen at the level of the pulmonary trunk in 2 patients (2%). Among the 7000 pulmonary arteries analyzed (5 central, 5 lobar, 20 segmental, and 40 subsegmental arteries/patient), pseudofilling defects were depicted at the level of 3 arteries (0.042%), always seen with the concurrent presence of a "double contour" appearance of the vessel walls. Twinkling star artifacts beyond the subsegmental level were seen within 76 segments (76/2000; 3.8% of the examined segments), most commonly in the lingula and left lower lobe. A total of 23 patients (23%) showed at least 1 category of motion artifacts, whereas 77 patients (77%) had motion-free imaging of the pulmonary arteries.

Conclusions: Routine scanning of patients with high pitch and high temporal resolution provides examinations devoid of detrimental cardiac motion artifacts.

Citing Articles

Free-Breathing, Non-Gated Heart-To-Brain CTA in Acute Ischemic Stroke: A Feasibility Study on Dual-Source CT.

Liu J, Wang C, Li Q, Duan X, Zhu X, Wang J Front Neurol. 2022; 13:616964.

PMID: 35273552 PMC: 8902348. DOI: 10.3389/fneur.2022.616964.


Coronary artery calcium scoring on non-gated, non-contrast chest computed tomography (CT) using wide-detector, high-pitch and fast gantry rotation: comparison with dedicated calcium scoring CT.

Shin J, Kim T, Kim J, Park C J Thorac Dis. 2020; 12(10):5783-5793.

PMID: 33209410 PMC: 7656362. DOI: 10.21037/jtd-20-1371.


Computed tomography pulmonary angiography using high-pitch dual-source scanner technology.

Al Hassan D, Waheed K, El Sirafy M, Khattab M, Al-Hammadi H, Ibrahim M Saudi Med J. 2019; 40(3):230-237.

PMID: 30834417 PMC: 6468199. DOI: 10.15537/smj.2019.3.23940.


Evaluation of the proximal coronary arteries in suspected pulmonary embolism: diagnostic images in 51% of patients using non-gated, dual-source CT pulmonary angiography.

Thomas D, McLaughlin P, Nugent J, Barrett S, Mayo J, Bilawich A Emerg Radiol. 2018; 26(2):189-194.

PMID: 30539378 DOI: 10.1007/s10140-018-01661-0.


Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality.

Gariani J, Martin S, Botsikas D, Becker C, Montet X Br J Radiol. 2018; 91(1088):20170443.

PMID: 29762055 PMC: 6209470. DOI: 10.1259/bjr.20170443.