» Articles » PMID: 23606904

Semiautomatic Segmentation of Ventilated Airspaces in Healthy and Asthmatic Subjects Using Hyperpolarized 3He MRI

Overview
Publisher Hindawi
Date 2013 Apr 23
PMID 23606904
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A segmentation algorithm to isolate areas of ventilation from hyperpolarized helium-3 magnetic resonance imaging (HP (3)He MRI) is described. The algorithm was tested with HP (3)He MRI data from four healthy and six asthmatic subjects. Ventilated lung volume (VLV) measured using our semiautomated technique was compared to that obtained from manual outlining of ventilated lung regions and to standard spirometric measurements. VLVs from both approaches were highly correlated (R = 0.99; P < 0.0001) with a mean difference of 3.8 mL and 95% agreement indices of -30.8 mL and 38.4 mL. There was no significant difference between the VLVs obtained through the semiautomatic approach and the manual approach. A Dice coefficient which quantified the intersection of the two datasets was calculated and ranged from 0.95 to 0.97 with a mean of 0.96 ± 0.01 (mean ± SD). VLVs obtained through the semiautomatic algorithm were also highly correlated with measurements of forced expiratory volume in one second (FEV1) (R = 0.82; P = 0.0035) and forced vital capacity (FVC) (R = 0.95; P < 0.0001). The technique may open new pathways toward advancing more quantitative characterization of ventilation for routine clinical assessment for asthma severity as well as a number of other respiratory diseases.

Citing Articles

Automatic lung segmentation in dynamic thoracic MRI using two-stage deep convolutional neural networks.

Xie L, Udupa J, Tong Y, McDonough J, Wu C, Lott C Proc SPIE Int Soc Opt Eng. 2023; 12032.

PMID: 36865001 PMC: 9977141. DOI: 10.1117/12.2612558.


Quantification of lung ventilation defects on hyperpolarized MRI: The Multi-Ethnic Study of Atherosclerosis (MESA) COPD study.

Zhang X, Angelini E, Haghpanah F, Laine A, Sun Y, Hiura G Magn Reson Imaging. 2022; 92:140-149.

PMID: 35777684 PMC: 9957614. DOI: 10.1016/j.mri.2022.06.016.


Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study.

Nguyen A, Perez-Rovira A, Wielopolski P, Hernandez Tamames J, Duijts L, De Bruijne M Eur Radiol. 2018; 29(6):2770-2782.

PMID: 30519932 PMC: 6510873. DOI: 10.1007/s00330-018-5863-7.


The role of heterogeneity in asthma: a structure-to-function perspective.

Lui J, Lutchen K Clin Transl Med. 2017; 6(1):29.

PMID: 28776171 PMC: 5543015. DOI: 10.1186/s40169-017-0159-0.


Linking Ventilation Heterogeneity Quantified via Hyperpolarized 3He MRI to Dynamic Lung Mechanics and Airway Hyperresponsiveness.

Lui J, Parameswaran H, Albert M, Lutchen K PLoS One. 2015; 10(11):e0142738.

PMID: 26569412 PMC: 4646346. DOI: 10.1371/journal.pone.0142738.


References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
de Lange E, Altes T, Patrie J, Gaare J, Knake J, Mugler 3rd J . Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry. Chest. 2006; 130(4):1055-62. DOI: 10.1378/chest.130.4.1055. View

3.
Tzeng Y, Lutchen K, Albert M . The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized 3He MRI. J Appl Physiol (1985). 2008; 106(3):813-22. DOI: 10.1152/japplphysiol.01133.2007. View

4.
Atkins M, Mackiewich B . Fully automatic segmentation of the brain in MRI. IEEE Trans Med Imaging. 1998; 17(1):98-107. DOI: 10.1109/42.668699. View

5.
Mullally W, Betke M, Albert M, Lutchen K . Explaining clustered ventilation defects via a minimal number of airway closure locations. Ann Biomed Eng. 2008; 37(2):286-300. PMC: 2934853. DOI: 10.1007/s10439-008-9603-z. View