Obstructive sleep apnea (OSA) diagnostics by the movement sensors static charge-sensitive bed (SCSB) and electromechanical film transducer (Emfit) is based on dividing the signal into different breathing patterns. The usage of non-invasive mattress sensors in diagnosing OSA is particularly tempting if patient has many other non sleep-related monitoring sensors. However, a systematic comparison of the apnea-hypopnea index (AHI) with Emfit-parameters is lacking. In addition to periodic breathing, SCSB and Emfit visualize episodes of sustained negative increases in intrathoracic pressure (increased respiratory resistance, IRR), of which relevance is still ambiguous. Our aim is to compare Emfit-parameters with the AHI and to provide a description of the patients suffering from IRR. Time percentage with all obstructive periodic Emfit breathing patterns (OPTotal%) showed the best correlation with the AHI. The OPTotal percentage of 21 yielded to excellent accuracy in detecting subjects with an AHI of 15/h or more. Patients with IRR received high scores in GHQ-12-questionnaire. An Emfit movement sensor might offer additional information in OSA diagnostics especially if nasal pressure transducer cannot be used.

Citing Articles

The Role of Novel Digital Clinical Tools in the Screening or Diagnosis of Obstructive Sleep Apnea: Systematic Review.

Duarte M, Pereira-Rodrigues P, Ferreira-Santos D J Med Internet Res. 2023; 25:e47735.

PMID: 37494079 PMC: 10413091. DOI: 10.2196/47735.


Description of a novel method for detection of sleep-disordered breathing in brachycephalic dogs.

Niinikoski I, Himanen S, Tenhunen M, Lilja-Maula L, Rajamaki M J Vet Intern Med. 2023; 37(4):1475-1481.

PMID: 37232547 PMC: 10365046. DOI: 10.1111/jvim.16783.


Device-based and subjective measurements of sleep in children with cerebral palsy: a comparison of sleep diary, actigraphy, and bed sensor data.

van Rijssen I, Hulst R, Gorter J, Gerritsen A, Visser-Meily J, Dudink J J Clin Sleep Med. 2022; 19(1):35-43.

PMID: 35975545 PMC: 9806786. DOI: 10.5664/jcsm.10246.


Emfit Bed Sensor Activity Shows Strong Agreement with Wrist Actigraphy for the Assessment of Sleep in the Home Setting.

Piantino J, Luther M, Reynolds C, Lim M Nat Sci Sleep. 2021; 13:1157-1166.

PMID: 34295199 PMC: 8291858. DOI: 10.2147/NSS.S306317.


Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study.

Hendriks M, van Lotringen J, Vos-van der Hulst M, Keijsers N JMIR Mhealth Uhealth. 2021; 9(2):e24339.

PMID: 33555268 PMC: 7971768. DOI: 10.2196/24339.