» Articles » PMID: 23577137

Enhanced Human Tissue Microdialysis Using Hydroxypropyl-ß-cyclodextrin As Molecular Carrier

Overview
Journal PLoS One
Date 2013 Apr 12
PMID 23577137
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Microdialysis sampling of lipophilic molecules in human tissues is challenging because protein binding and adhesion to the membrane limit recovery. Hydroxypropyl-ß-cyclodextrin (HP-ß-CD) forms complexes with hydrophobic molecules thereby improving microdialysis recovery of lipophilic molecules in vitro and in rodents. We tested the approach in human subjects. First, we determined HP-ß-CD influences on metabolite stability, delivery, and recovery in vitro. Then, we evaluated HP-ß-CD as microdialysis perfusion fluid supplement in 20 healthy volunteers. We placed 20 kDa microdialysis catheters in subcutaneous abdominal adipose tissue and in the vastus lateralis muscle. We perfused catheters with lactate free Ringer solution with or without 10% HP-ß-CD at flow rates of 0.3-2.0 µl/min. We assessed tissue metabolites, ultrafiltration effects, and blood flow. In both tissues, metabolite concentrations with Ringer+HP-ß-CD perfusate were equal or higher compared to Ringer alone. Addition of HP-ß-CD increased dialysate volume by 10%. Adverse local or systemic reactions to HP-ß-CD did not occur and analytical methods were not disturbed. HP-ß-CD addition allowed to measure interstitial anandamide concentrations, a highly lipophilic endogenous molecule. Our findings suggest that HP-ß-CD is a suitable supplement in clinical microdialysis to enhance recovery of lipophilic molecules from human interstitial fluid.

Citing Articles

A rapid screening method to select microdialysis carriers for hydrophobic compounds.

Wang S, Lu H, Wang Y, Huang H, Yang C PLoS One. 2021; 16(9):e0256920.

PMID: 34469501 PMC: 8409685. DOI: 10.1371/journal.pone.0256920.


A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts.

Kho C, Enche Ab Rahim S, Ahmad Z, Abdullah N Mol Neurobiol. 2016; 54(5):3506-3527.

PMID: 27189617 DOI: 10.1007/s12035-016-9929-8.


Combined Microdialysis-Tumor Homogenate Method for the Study of the Steady State Compartmental Distribution of a Hydrophobic Anticancer Drug in Patient-Derived Xenografts.

Monterrubio C, Paco S, Vila-Ubach M, Rodriguez E, Glisoni R, Lavarino C Pharm Res. 2015; 32(9):2889-900.

PMID: 25773723 DOI: 10.1007/s11095-015-1671-9.


A water-soluble inclusion complex of pedunculoside with the polymer β-cyclodextrin: a novel anti-inflammation agent with low toxicity.

Liu C, Zhang W, Yang H, Sun W, Gong X, Zhao J PLoS One. 2014; 9(7):e101761.

PMID: 25013908 PMC: 4094462. DOI: 10.1371/journal.pone.0101761.


Clinical evaluation of extracellular ADMA concentrations in human blood and adipose tissue.

May M, Batkai S, Zorner A, Tsikas D, Jordan J, Engeli S Int J Mol Sci. 2014; 15(1):1189-200.

PMID: 24445256 PMC: 3907863. DOI: 10.3390/ijms15011189.

References
1.
Farnebo S, Zettersten E, Samuelsson A, Tesselaar E, Sjoberg F . Assessment of blood flow changes in human skin by microdialysis urea clearance. Microcirculation. 2010; 18(3):198-204. DOI: 10.1111/j.1549-8719.2010.00077.x. View

2.
Zoerner A, Rakers C, Engeli S, Batkai S, May M, Jordan J . Peripheral endocannabinoid microdialysis: in vitro characterization and proof-of-concept in human subjects. Anal Bioanal Chem. 2012; 402(9):2727-35. DOI: 10.1007/s00216-012-5729-9. View

3.
Sun L, Stenken J . Improving microdialysis extraction efficiency of lipophilic eicosanoids. J Pharm Biomed Anal. 2003; 33(5):1059-71. DOI: 10.1016/s0731-7085(03)00363-7. View

4.
Tholance Y, Barcelos G, Quadrio I, Renaud B, Dailler F, Perret-Liaudet A . Analytical validation of microdialysis analyzer for monitoring glucose, lactate and pyruvate in cerebral microdialysates. Clin Chim Acta. 2010; 412(7-8):647-54. DOI: 10.1016/j.cca.2010.12.025. View

5.
Sun L, Stenken J . The effect of beta-cyclodextrin on liquid chromatography/electrospray-mass spectrometry analysis of hydrophobic drug molecules. J Chromatogr A. 2007; 1161(1-2):261-8. DOI: 10.1016/j.chroma.2007.05.104. View