The Performance of 2D Array Detectors for Light Sheet Based Fluorescence Correlation Spectroscopy

Overview
Journal Opt Express
Date 2013 Apr 11
PMID 23571955
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Single plane illumination microscopy based fluorescence correlation spectroscopy (SPIM-FCS) is a new method for imaging FCS in 3D samples, providing diffusion coefficients, transport, flow velocities and concentrations in an imaging mode. SPIM-FCS records correlation functions over a whole plane in a sample, which requires array detectors for recording the fluorescence signal. Several types of image sensors are suitable for FCS. They differ in properties such as effective area per pixel, quantum efficiency, noise level and read-out speed. Here we compare the performance of several low light array detectors based on three different technologies: (1) Single-photon avalanche diode (SPAD) arrays, (2) passive-pixel electron multiplying charge coupled device (EMCCD) and (3) active-pixel scientific-grade complementary metal oxide semiconductor cameras (sCMOS). We discuss the influence of the detector characteristics on the effective FCS observation volume, and demonstrate that light sheet based SPIM-FCS provides absolute diffusion coefficients. This is verified by parallel measurements with confocal FCS, single particle tracking (SPT), and the determination of concentration gradients in space and time. While EMCCD cameras have a temporal resolution in the millisecond range, sCMOS cameras and SPAD arrays can extend the time resolution of SPIM-FCS down to 10 μs or lower.

Citing Articles

A practical guide to light-sheet microscopy for nanoscale imaging: Looking beyond the cell.

Kramer S, Antarasen J, Reinholt C, Kisley L J Appl Phys. 2024; 136(9):091101.

PMID: 39247785 PMC: 11380115. DOI: 10.1063/5.0218262.


Wide-field intensity fluctuation imaging.

Fang Q, Tomar A, Dunn A Biomed Opt Express. 2024; 15(2):1004-1020.

PMID: 38404351 PMC: 10890890. DOI: 10.1364/BOE.506870.


Deep learning reduces data requirements and allows real-time measurements in imaging FCS.

Tang W, Sim S, Aik D, Nelanuthala A, Athilingam T, Rollin A Biophys J. 2023; 123(6):655-666.

PMID: 38050354 PMC: 10995408. DOI: 10.1016/j.bpj.2023.11.3403.


Wide-field Intensity Fluctuation Imaging.

Fang Q, Tomar A, Dunn A bioRxiv. 2023; .

PMID: 37546910 PMC: 10402166. DOI: 10.1101/2023.07.29.551117.


Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array.

Samimi K, Desa D, Lin W, Weiss K, Li J, Huisken J J Biomed Opt. 2023; 28(6):066502.

PMID: 37351197 PMC: 10284079. DOI: 10.1117/1.JBO.28.6.066502.