» Articles » PMID: 23563339

Impact of Starting Point and Bicortical Purchase of C1 Lateral Mass Screws on Atlantoaxial Fusion: Meta-Analysis and Review of the Literature

Overview
Specialty Orthopedics
Date 2013 Apr 9
PMID 23563339
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Study Design: Structured review of literature and application of meta-analysis statistical techniques.

Objectives: Review published series describing clinical and radiographic outcomes of patients treated with C1 lateral mass screws (C1LMS), specifically analyzing the impact of starting point and bicortical purchase on successful atlantoaxial arthrodesis.

Summary Of Background Data: Biomechanical studies suggest posterior arch screws and C1LMS with bicortical purchase are stronger than screws placed within the center of the lateral mass or those with unicortical purchase.

Methods: Online databases were searched for English-language articles between 1994 and 2012 describing posterior atlantal instrumentation with C1LMS. Thirty-four studies describing 1247 patients having posterior atlantoaxial fusion with C1LMS met inclusion criteria.

Results: All studies provided class III evidence. Arthrodesis was quite successful regardless of technique (99.0% overall). Meta-analysis and multivariate regression analyses showed that neither posterior arch starting point nor bicortical screw purchase translated into a higher rate of successful arthrodesis. There were no complications from bicortical screw purchase.

Conclusions: The Goel-Harms technique is a very safe and successful technique for achieving atlantoaxial fusion, regardless of minor variations in C1LMS technique. Although biomechanical studies suggest markedly increased rigidity of bicortical and posterior arch C1LMS, the significance of these findings may be minimal in the clinical setting of atlantoaxial fixation and fusion with modern techniques. The decision to use either technique must be made after careful review of the preoperative multiplanar computed tomography imaging, assessment of the unique anatomy of each patient, and the demands of the clinical scenario such as bone quality.

Citing Articles

Posterior atlantoaxial fusion: a comprehensive review of surgical techniques and relevant vascular anomalies.

Chen Q, Brahimaj B, Khanna R, Kerolus M, Tan L, David B J Spine Surg. 2020; 6(1):164-180.

PMID: 32309655 PMC: 7154353. DOI: 10.21037/jss.2020.03.05.


Usefulness of a New Electronic Conductivity Device with a Pedicle Probe and a Multi-axis Angiography Unit for Inserting a C1 Lateral Mass Screw Safely and Tightly: A Technical Note.

Kageyama H, Yoshimura S, Matsuda K, Yoshida Y, Matsukawa H, Yamada K Neurol Med Chir (Tokyo). 2019; 59(12):523-528.

PMID: 31656253 PMC: 6923162. DOI: 10.2176/nmc.tn.2019-0025.


[Importance of C1 pedicle screws in the Goel-Harms technique].

Kobbe P, Kandziora F, Hildebrand F, Scholz M Unfallchirurg. 2017; 120(12):1096.

PMID: 29063169 DOI: 10.1007/s00113-017-0432-0.


Applied anatomy of screw placement via the posterior arch of the atlas and anatomy-based refinements of the technique.

Bodon G, Grimm A, Hirt B, Seifarth H, Barsa P Eur J Orthop Surg Traumatol. 2016; 26(7):793-803.

PMID: 27106585 DOI: 10.1007/s00590-016-1771-1.


Occipitocervical fusion with relief of odontoid invagination: atlantoaxial distraction method using cylindrical titanium cage for basilar invagination--case report.

Yoshizumi T, Murata H, Ikenishi Y, Sato M, Takase H, Tateishi K Neurosurg Rev. 2014; 37(3):519-24.

PMID: 24553815 DOI: 10.1007/s10143-014-0531-0.