» Articles » PMID: 23498688

Polythiophene-coated Fe3O4 Superparamagnetic Nanocomposite: Synthesis and Application As a New Sorbent for Solid-phase Extraction

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2013 Mar 19
PMID 23498688
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

In the present work, a novel type of superparamagnetic nanosorbent, polythiophene-coated Fe3O4 nanoparticles (Fe3O4@PTh NPs), have been successfully synthesized. The synthesized NPs were characterized by scanning electron microscopy (SEM), Fourier transform-infrared (FT-IR) spectroscopy, and thermal gravimetric analysis (TGA). The synthesized Fe3O4@PTh NPs were applied as an efficient sorbent for extraction and preconcentration of several typical plasticizer compounds (di-n-butyl phthalate (DBP), di-(2-ethylhexyl) phthalate (DEHP), and dioctyl adipate (DOA)) from environmental water samples. Separation of Fe3O4@PTh NPs from the aqueous solution was simply achieved by applying external magnetic field. Separation and determination of the extracted plasticizers was performed by gas chromatography-flame ionization detection (GC-FID). Several variables affecting the extraction efficiency of the analytes i.e., amount of NPs sorbent, salt concentration, extraction time, and desorption conditions were investigated and optimized. The best working conditions were as follows: amount of sorbent, 100 mg; NaCl concentration, 30% (w/v); sample volume, 45 mL; extraction time, 10 min; and 100 μL of ethyl acetate for desorption of the analytes within 2 min. Under optimized conditions, preconcentration factors for DBP, DEHP, and DOA were obtained as 86, 194, and 213, respectively. The calibration curves were linear (R(2)>0.998) in the concentration range of 0.4-100 μg L(-1) for both DEHP and DOA and 0.7-100 μg L(-1) for DBP. The limits of detection (LODs) were obtained in the range of 0.2-0.4 μg L(-1). The intra-day relative standard deviations (RSDs%) based on four replicates were obtained in the range of 4.0-12.3%. The proposed procedure was applied to analysis of water samples including river water, bottled mineral water, and boiling water exposed to polyethylene container (after cooling) and recoveries between 85 and 99% and RSDs lower than 12.8% were obtained.

Citing Articles

Unpacking Phthalates from Obscurity in the Environment.

Baneshi M, Tonney-Gagne J, Halilu F, Pilavangan K, Sabu Abraham B, Prosser A Molecules. 2024; 29(1).

PMID: 38202689 PMC: 10780137. DOI: 10.3390/molecules29010106.


A Review: Using Multiple Templates for Molecular Imprinted Polymer: Is It Good?.

Murdaya N, Triadenda A, Rahayu D, Hasanah A Polymers (Basel). 2022; 14(20).

PMID: 36298019 PMC: 9610782. DOI: 10.3390/polym14204441.


Magnetic solid-phase extraction using a mixture of two types of nanoparticles followed by gas chromatography-mass spectrometry for the determination of six phthalic acid esters in various water samples.

Li H, Cao Z, Cao X, Jiang Z, Abd El-Aty A, Qi Y RSC Adv. 2022; 8(69):39641-39649.

PMID: 35558051 PMC: 9090721. DOI: 10.1039/c8ra08643e.


A new core-shell magnetic mesoporous surface molecularly imprinted composite and its application as an MSPE sorbent for determination of phthalate esters.

Liu Y, Song W, Zhou D, Han F, Gong X, Pan P RSC Adv. 2022; 12(12):7253-7261.

PMID: 35424702 PMC: 8982323. DOI: 10.1039/d1ra09405j.


Reduced graphene-decorated covalent organic framework as a novel coating for solid-phase microextraction of phthalate esters coupled to gas chromatography-mass spectrometry.

Khataei M, Yamini Y, Ghaemmaghami M Mikrochim Acta. 2020; 187(4):256.

PMID: 32240388 DOI: 10.1007/s00604-020-4224-9.