» Articles » PMID: 23436443

Evaluation of a Non-invasive Monitoring Method for Free Flap Breast Reconstruction Using Laser Doppler Flowmetrie and Tissue Spectrophotometry

Overview
Journal Microsurgery
Date 2013 Feb 26
PMID 23436443
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Despite advances in the monitoring of free flaps, there is still a demand for new technology to detect ischemic complications at an early stage. The aim of the present study was to evaluate the reliability of the O2C-device in terms of detecting flap failure in commonly used perforator flaps for breast reconstruction.

Methods: A total of 34 patients undergoing breast reconstruction were involved in this study. The perfusion dynamics of 23 deep inferior epigastric perforator flaps and 11 superior gluteal arterial perforator flaps were assessed using the O2C-device, which combines a laser light, to determine blood flow (flow), velocity, and white light to determine hemoglobin oxygenation (SO(2)) and relative amount of hemoglobin (rHB). Measurements were carried out intra-operatively after clamping and declamping the perforator vessels. In the post-operative period measurements were carried out every hour for the first 48 hours and from 3rd to 7th for every 2 hours. These dates were compared to findings of clinical assessment.

Results: Several intra-operative measurements, during the clamping and declamping the different perforator vessels, revealed a high correlation for all parameters: Flow (r = 0.89, P < 0. 05), Velo (r = 0.92, P < 0. 05), SO2 (r =0.84, P <0. 05), and rHB (r =0.83 P < 0.05). Vessel occlusion was detected in five cases, of which three were due to arterial thrombosis and two further cases were due to venous occlusion. Of the five cases, one flap loss caused by venous occlusion was noted.

Conclusion: The O2C-device seems to be a reliable, objective, and non-invasive device for the monitoring of free flaps. Thus, it may improve flap survival rates by detecting vascular compromise at an early stage.

Citing Articles

Changes in the Microcirculation and Physiologic Perfusion Dynamics of Free DIEP Flaps in the First 72 h After Breast Reconstruction.

Ehrl D, Alt V, Taha S, Frank K, Wachtel N, Bodenschatz K J Clin Med. 2025; 14(2).

PMID: 39860525 PMC: 11765763. DOI: 10.3390/jcm14020520.


Assessing the Effect of Enzymatic Debridement on the Scar Quality in Partial-Thickness Burns to Deep Dermal Burns of the Hand: A Long-Term Evaluation.

Heitzmann W, Schulz A, Fuchs P, Schiefer J Medicina (Kaunas). 2024; 60(3).

PMID: 38541207 PMC: 10972138. DOI: 10.3390/medicina60030481.


Evaluation of Scar Quality after Treatment of Superficial Burns with Dressilk and Suprathel-In an Intraindividual Clinical Setting.

Schiefer J, Andreae J, Fuchs P, Lefering R, Heidekrueger P, Schulz A J Clin Med. 2022; 11(10).

PMID: 35628983 PMC: 9144963. DOI: 10.3390/jcm11102857.


Comparing the Time-Dependent Evolution of Microcirculation in Gracilis vs. ALT Flaps Using Laser-Doppler Flowmetry and Tissue-Spectrometry.

Moellhoff N, Heidekrueger P, Frank K, Pistek S, Alt V, Giunta R J Clin Med. 2022; 11(9).

PMID: 35566551 PMC: 9099565. DOI: 10.3390/jcm11092425.


Standardized Skin Flap Warming Effectively Improves Flap Survival without Obstructing Temperature Monitoring after DIEP.

Wang Y, Wu G, Chu C, Li X, Zou Q, Cao Y Plast Reconstr Surg Glob Open. 2022; 10(2):e4153.

PMID: 35242493 PMC: 8884534. DOI: 10.1097/GOX.0000000000004153.