» Articles » PMID: 23399025

Head-and-face Shape Variations of U.S. Civilian Workers

Overview
Journal Appl Ergon
Specialty Psychology
Date 2013 Feb 13
PMID 23399025
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this study was to quantify head-and-face shape variations of U.S. civilian workers using modern methods of shape analysis. The purpose of this study was based on previously highlighted changes in U.S. civilian worker head-and-face shape over the last few decades - touting the need for new and better fitting respirators - as well as the study's usefulness in designing more effective personal protective equipment (PPE) - specifically in the field of respirator design. The raw scan three-dimensional (3D) data for 1169 subjects were parameterized using geometry processing techniques. This process allowed the individual scans to be put in correspondence with each other in such a way that statistical shape analysis could be performed on a dense set of 3D points. This process also cleaned up the original scan data such that the noise was reduced and holes were filled in. The next step, statistical analysis of the variability of the head-and-face shape in the 3D database, was conducted using Principal Component Analysis (PCA) techniques. Through these analyses, it was shown that the space of the head-and-face shape was spanned by a small number of basis vectors. Less than 50 components explained more than 90% of the variability. Furthermore, the main mode of variations could be visualized through animating the shape changes along the PCA axes with computer software in executable form for Windows XP. The results from this study in turn could feed back into respirator design to achieve safer, more efficient product style and sizing. Future study is needed to determine the overall utility of the point cloud-based approach for the quantification of facial morphology variation and its relationship to respirator performance.

Citing Articles

A parametric design framework for the mass customization of bicycle helmet.

Zhu Z, Huang Y, Ji W, Zhu J, Wang W Heliyon. 2024; 10(5):e27409.

PMID: 38463891 PMC: 10923842. DOI: 10.1016/j.heliyon.2024.e27409.


Head stabilization apparatus for high-resolution ophthalmic imaging.

Vienola K, Holmes J, Glasso Z, Rossi E Appl Opt. 2024; 63(4):940-944.

PMID: 38437390 PMC: 11210293. DOI: 10.1364/AO.513801.


Overview of tight fit and infection prevention benefits of respirators (filtering face pieces).

Knobloch J, Franke G, Knobloch M, Knobling B, Kampf G J Hosp Infect. 2023; 134:89-96.

PMID: 36738992 PMC: 9894678. DOI: 10.1016/j.jhin.2023.01.009.


Head and face anthropometric study for respirators in the multi-ethnic Asian population of Malaysia.

Lim Y, Shakor A, Mohamad N, Pahrol M, Ismail R, Chong Z Front Public Health. 2022; 10:972249.

PMID: 36091510 PMC: 9459016. DOI: 10.3389/fpubh.2022.972249.


The influence of gender and ethnicity on facemasks and respiratory protective equipment fit: a systematic review and meta-analysis.

Chopra J, Abiakam N, Kim H, Metcalf C, Worsley P, Cheong Y BMJ Glob Health. 2021; 6(11).

PMID: 34764145 PMC: 8587533. DOI: 10.1136/bmjgh-2021-005537.


References
1.
Oestenstad R, PERKINS J, Rose V . Identification of faceseal leak sites on a half-mask respirator. Am Ind Hyg Assoc J. 1990; 51(5):280-4. DOI: 10.1080/15298669091369655. View

2.
Zhuang Z, Bradtmiller B . Head-and-face anthropometric survey of U.S. respirator users. J Occup Environ Hyg. 2005; 2(11):567-76. DOI: 10.1080/15459620500324727. View

3.
Zhuang Z, Bradtmiller B, Shaffer R . New respirator fit test panels representing the current U.S. civilian work force. J Occup Environ Hyg. 2007; 4(9):647-59. DOI: 10.1080/15459620701497538. View

4.
Zhuang Z, Benson S, Viscusi D . Digital 3-D headforms with facial features representative of the current US workforce. Ergonomics. 2010; 53(5):661-71. DOI: 10.1080/00140130903581656. View

5.
Roberge R, Monaghan W, Palmiero A, Shaffer R, Bergman M . Infrared imaging for leak detection of N95 filtering facepiece respirators: a pilot study. Am J Ind Med. 2011; 54(8):628-36. DOI: 10.1002/ajim.20970. View