» Articles » PMID: 23392728

Light Curing Through Glass Ceramics with a Second- and a Third-generation LED Curing Unit: Effect of Curing Mode on the Degree of Conversion of Dual-curing Resin Cements

Overview
Specialty Dentistry
Date 2013 Feb 9
PMID 23392728
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM).

Materials And Methods: Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance-Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05).

Results: Maximum irradiances were 1,545 mW/cm(2) (SM), 2,179 mW/cm(2) (HPM), and 4,156 mW/cm(2) (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC.

Conclusions: Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others.

Clinical Relevance: When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.

Citing Articles

Mechanical Properties of Alkasite Material with Different Curing Modes and Simulated Aging Conditions.

Mandic V, Plancak L, Marovic D, Tarle Z, Trutina Gavran M, Par M Materials (Basel). 2024; 17(11).

PMID: 38894041 PMC: 11173928. DOI: 10.3390/ma17112777.


Light Polymerization through Glass-ceramics: Influence of Light-polymerizing Unit's Emitted Power and Restoration Parameters (Shade, Translucency, and Thickness) on Transmitted Radiant Power.

Farah R, Alblihed I, Aljuoie A, Alresheedi B Contemp Clin Dent. 2024; 15(1):35-43.

PMID: 38707663 PMC: 11068246. DOI: 10.4103/ccd.ccd_124_23.


Adhesive Performance Assessment of Universal Adhesives and Universal Adhesive/Composite Cement Combinations.

Tang C, Mercelis B, Ahmed M, Yoshihara K, Peumans M, Van Meerbeek B J Adhes Dent. 2023; 25():241-256.

PMID: 37975313 PMC: 11734254. DOI: 10.3290/j.jad.b4646953.


Effect of Attenuated Light Through Translucent Zirconia on the Interfacial Adaptation and Polymerization of Resin Cements.

Han S, Shimada Y, Sadr A, Tabata T, Nakagawa H, Sato T J Adhes Dent. 2023; 25():219-230.

PMID: 37910068 PMC: 11734313. DOI: 10.3290/j.jad.b4586857.


Post-Cure Development of the Degree of Conversion and Mechanical Properties of Dual-Curing Resin Cements.

Carek A, Dukaric K, Miler H, Marovic D, Tarle Z, Par M Polymers (Basel). 2022; 14(17).

PMID: 36080725 PMC: 9460751. DOI: 10.3390/polym14173649.


References
1.
Ferracane J, MITCHEM J, Condon J, Todd R . Wear and marginal breakdown of composites with various degrees of cure. J Dent Res. 1997; 76(8):1508-16. DOI: 10.1177/00220345970760081401. View

2.
Koch A, Kroeger M, Hartung M, Manetsberger I, Hiller K, Schmalz G . Influence of ceramic translucency on curing efficacy of different light-curing units. J Adhes Dent. 2008; 9(5):449-62. View

3.
Caughman W, Caughman G, Shiflett R, Rueggeberg F, Schuster G . Correlation of cytotoxicity, filler loading and curing time of dental composites. Biomaterials. 1991; 12(8):737-40. DOI: 10.1016/0142-9612(91)90022-3. View

4.
Asmussen E, Peutzfeldt A . Polymerization contraction of resin composite vs. energy and power density of light-cure. Eur J Oral Sci. 2005; 113(5):417-21. DOI: 10.1111/j.1600-0722.2005.00239.x. View

5.
Flury S, Peutzfeldt A, Lussi A . The effect of polymerization procedure on Vickers hardness of dual-curing resin cements. Am J Dent. 2011; 24(4):226-32. View