Troubleshooting Carry-over of LC-MS/MS Method for Rifampicin, Clarithromycin and Metabolites in Human Plasma

Overview
Publisher Elsevier
Date 2013 Jan 29
PMID 23353809
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Clarithromycin and rifampicin are used for the treatment of Mycobacteria. Pharmacokinetic drug interaction is possibly due to the influence of the two drugs on the liver enzymes. Using a Hypurity Aquastar C18 column (50mm×2.1mm×5μm) for liquid chromatography including a polar end-capped phase for the determination of clarithromycin, rifampicin and their metabolites together in plasma using LC-MS/MS resulted in a substantial carry-over. As a consequence, the throughput of the method is not assured. Using a step-by-step troubleshooting procedure, such carry-over was found originating from column memory effect. With the use of another type of C18 column, the carry-over is eliminated. Due to the absence of carry-over, the analytical concentration ranges are extended and are therefore more appropriate for the analysis of patient samples. The method was re-validated for linearity, reproducibility and dilution integrity.

Citing Articles

A Simple UPLC-MS/MS Assay of Rifampin in a Small Volume of Human Plasma.

Sano T, Ishii T, Hotta K, Mano Y ACS Omega. 2023; 8(39):36261-36268.

PMID: 37810660 PMC: 10552088. DOI: 10.1021/acsomega.3c04814.


Simultaneous determination of first-line anti-tuberculosis drugs and one metabolite of isoniazid by liquid chromatography/tandem mass spectrometry in patients with human immunodeficiency virus-tuberculosis coinfection.

Xing Y, Yin L, Le X, Chen J, Zhang L, Li Y Heliyon. 2021; 7(7):e07532.

PMID: 34296020 PMC: 8282971. DOI: 10.1016/j.heliyon.2021.e07532.


Determination of Crizotinib in Mouse Tissues by LC-MS/MS and Its Application to a Tissue Distribution Study.

Zhao F, Wei Y, Yan Y, Liu H, Zhou S, Ren B Int J Anal Chem. 2020; 2020:8837254.

PMID: 33381185 PMC: 7762669. DOI: 10.1155/2020/8837254.


Troubleshooting Carry-Over in the LC-MS Analysis of Biomolecules: The Case of Neuropeptide Y.

Yamagaki T, Yamazaki T Mass Spectrom (Tokyo). 2020; 8(2):S0083.

PMID: 33299733 PMC: 7709882. DOI: 10.5702/massspectrometry.S0083.


Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma.

Temova Rakusa Z, Roskar R, Klancar Andrejc A, Trdan Lusin T, Faganeli N, Grabnar I Int J Anal Chem. 2019; 2019:4848236.