» Articles » PMID: 23344681

Intraoperative Spinal Cord Monitoring During the Surgical Correction of Scoliosis Due to Cerebral Palsy and Other Neuromuscular Disorders

Overview
Journal Eur Spine J
Specialty Orthopedics
Date 2013 Jan 25
PMID 23344681
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Patients with neuromuscular scoliosis are at increased risk of neurological deficit post-operatively, but are a difficult population on whom to perform neurophysiological monitoring. We look here at a 7-year sample of our practice in the monitoring of neuromuscular patients.

Methods: A retrospective chart review was performed for 109 patients who underwent correction of neuromuscular scoliosis within our institution between 2005 and 2011.

Results: Of 109 patients who were identified, intraoperative monitoring was attempted in 66 cases. In eight cases (13 %), no reliable monitoring could be achieved and was therefore abandoned. On nine occasions, there was a significant drop in at least one modality intraoperatively. None of these nine suffered any clinically observable neurological deficit post-operatively. Of the 109 patients, 2 had clinically detectable deficits post-operatively, both of whom had undergone normal intraoperative monitoring.

Conclusions: The two patients with observable deficit had their instrumentation left in situ after discussion with them and/or parents. Spinal cord monitoring in this population is possible but potentially unreliable. Surgeons will need to carefully consider the use of monitoring in their management of this challenging population.

Citing Articles

Minimally Invasive Bipolar Technique for Scoliosis in Rett Syndrome-Results and Complications in a Series of 22 Cases.

Del Sal A, Haumont E, Pigeolet M, Gaume M, Riouallon G, Bahi Buisson N J Clin Med. 2025; 14(3).

PMID: 39941520 PMC: 11818170. DOI: 10.3390/jcm14030849.


Surgical complications in neuromuscular scoliosis surgery: systematic review and meta-analysis of the last ten years.

Elmeshneb M, Hassanin M, Elnady B, Sleem A, Le G, Patel M Eur Spine J. 2024; 33(7):2666-2676.

PMID: 38869648 DOI: 10.1007/s00586-024-08338-y.


Neuromuscular Monitoring and Wake-Up Test During Scoliosis Surgery.

Paunikar S, Paul A, Wanjari D, Alaspurkar N Cureus. 2023; 15(8):e44046.

PMID: 37746490 PMC: 10517712. DOI: 10.7759/cureus.44046.


Transcranial electric motor evoked potential monitoring during scoliosis surgery in children with cerebral palsy and active seizure disorder: is it feasible and safe?.

Shrader M, DiCindio S, Kenny K, Franco A, Zhang R, Theroux M Spine Deform. 2023; 11(6):1461-1466.

PMID: 37458896 DOI: 10.1007/s43390-023-00730-w.


Intra-Operative Neurophysiological Monitoring in Patients with Thoracic Spinal Stenosis: Its Feasibility and High-Risk Factors for New Neurological Deficit.

Liu W, Li Y, Qiu J, Shi B, Liu Z, Sun X Orthop Surg. 2023; 15(5):1298-1303.

PMID: 37052070 PMC: 10157703. DOI: 10.1111/os.13724.


References
1.
Jones K, Sponseller P, Shindle M, McCarthy M . Longitudinal parental perceptions of spinal fusion for neuromuscular spine deformity in patients with totally involved cerebral palsy. J Pediatr Orthop. 2003; 23(2):143-9. View

2.
Eccher M . Intraoperative neurophysiologic monitoring: are we really that bad?. J Clin Neurophysiol. 2012; 29(2):157-9. DOI: 10.1097/WNP.0b013e31824ff6d0. View

3.
Padberg A, Russo M, Lenke L, Bridwell K, Komanetsky R . Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery. J Spinal Disord. 1996; 9(2):150-8. View

4.
DiCindio S, Theroux M, Shah S, Miller F, Dabney K, Brislin R . Multimodality monitoring of transcranial electric motor and somatosensory-evoked potentials during surgical correction of spinal deformity in patients with cerebral palsy and other neuromuscular disorders. Spine (Phila Pa 1976). 2003; 28(16):1851-5; discussion 1855-6. DOI: 10.1097/01.BRS.0000083202.62956.A8. View

5.
Fehlings M, Kelleher M . Intraoperative monitoring during spinal surgery for neuromuscular scoliosis. Nat Clin Pract Neurol. 2007; 3(6):318-9. DOI: 10.1038/ncpneuro0502. View