Journal Lasers Surg Med
Date 2013 Jan 3
PMID 23280439
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objective: Preclinical studies suggest an increased vaporization rate and speed of the 532 nm 180-W XPS GreenLight laser (180-W) compared with the 120-W HPS GreenLight laser (120-W) and the 80-W PV GreenLight laser (80-W). To test the clinical relevance of this observation we analyzed intraoperative data and early postoperative results after photoselective vaporization of the prostate (PVP) with the 180-W, 120-W, and 80-W laser.

Study Design/materials And Methods: A retrospective pair-to-pair comparison was performed including 80 consecutive patients who underwent PVP for the treatment of benign prostate enlargement with the 180-W, 120-W, and 80-W laser. The groups matched concerning age, prostate volume, PSA-value, and preoperative catheterization. Primary study outcome measurement was PSA-value reduction at 3 months; intraoperative data, perioperative complications, and early postoperative functional course were secondary study outcome measurements.

Results: Energy application per case (kJ), preoperative prostate volume (kJ/ml) operating time (kJ/minute), and lasing time (kJ/minute) was significantly higher with the 180-W laser. Prevalence of impaired visibility due to bleeding was comparable between the 180-W and the 120-W laser but significantly lower with 80-W. Duration of hospitalization was shorter with the 180-W laser compared to the former laser systems. During the postoperative course of 3 months voiding parameters and micturition symptoms significantly improved in all groups, the incidence of postoperative dysuria was comparable. Postoperative PSA-value reduction was significantly higher after treatment with the 180-W laser.

Conclusions: With the 180-W laser, higher energy application and higher speed of tissue vaporization leads to increased tissue vaporization compared to the former 120-W and 80-W laser systems. Clinical efficacy and perioperative safety are maintained with the higher powered laser.

Citing Articles

Comparative efficacy and safety of 180 W XPS . 120 W HPS GreenLight laser therapy for benign prostatic hyperplasia: a systematic review and meta-analysis.

Wang M, Xi Y, Qiu Z, Huang N, Zhang L, Liu J PeerJ. 2024; 12:e18615.

PMID: 39619178 PMC: 11608016. DOI: 10.7717/peerj.18615.


GreenLight Laser™ Photovaporization versus Transurethral Resection of the Prostate: A Systematic Review and Meta-Analysis.

Castellani D, Pirola G, Rubilotta E, Gubbiotti M, Scarcella S, Maggi M Res Rep Urol. 2021; 13:263-271.

PMID: 34295844 PMC: 8290851. DOI: 10.2147/RRU.S277482.


Shedding light on polypragmasy of pain after transurethral prostate surgery procedures: a systematic review and meta-analysis.

Wroclawski M, Castellani D, Heldwein F, Teles S, Cha J, Zhao H World J Urol. 2021; 39(10):3711-3720.

PMID: 33787985 DOI: 10.1007/s00345-021-03678-6.


Absorption of irrigation fluid during XPS™ GreenLight laser vaporization of the prostate: results from a prospective breath ethanol monitoring study.

Wettstein M, Poyet C, Grossmann N, Fankhauser C, Keller E, Kozomara M World J Urol. 2016; 34(9):1261-7.

PMID: 26780733 DOI: 10.1007/s00345-016-1766-x.


The 80-W KTP GreenLight laser vaporization of the prostate versus transurethral resection of the prostate (TURP): adjusted analysis of 5-year results of a prospective non-randomized bi-center study.

Guo S, Muller G, Lehmann K, Talimi S, Bonkat G, Puschel H Lasers Med Sci. 2015; 30(3):1147-51.

PMID: 25698433 DOI: 10.1007/s10103-015-1721-x.