» Articles » PMID: 23273841

CEST: from Basic Principles to Applications, Challenges and Opportunities

Overview
Journal J Magn Reson
Publisher Elsevier
Date 2013 Jan 1
PMID 23273841
Citations 143
Authors
Affiliations
Soon will be listed here.
Abstract

Chemical Exchange Saturation Transfer (CEST) offers a new type of contrast for MRI that is molecule specific. In this approach, a slowly exchanging NMR active nucleus, typically a proton, possessing a chemical shift distinct from water is selectively saturated and the saturated spin is transferred to the bulk water via chemical exchange. Many molecules can act as CEST agents, both naturally occurring endogenous molecules and new types of exogenous agents. A large variety of molecules have been demonstrated as potential agents, including small diamagnetic molecules, complexes of paramagnetic ions, endogenous macromolecules, dendrimers and liposomes. In this review we described the basic principles of the CEST experiment, with emphasis on the similarity to earlier saturation transfer experiments described in the literature. Interest in quantitative CEST has also resulted in the development of new exchange-sensitive detection schemes. Some emerging clinical applications of CEST are described and the challenges and opportunities associated with translation of these methods to the clinical environment are discussed.

Citing Articles

Gadolinium-Based Contrast Agents (GBCAs) for MRI: A Benefit-Risk Balance Analysis from a Chemical, Biomedical, and Environmental Point of View.

Scarciglia A, Papi C, Romiti C, Leone A, Di Gregorio E, Ferrauto G Glob Chall. 2025; 9(3):2400269.

PMID: 40071223 PMC: 11891575. DOI: 10.1002/gch2.202400269.


Detection of breast cancer lesions using APT weighted MRI: a systematic review.

Lee R, Boparai M, Duong T J Transl Med. 2025; 23(1):141.

PMID: 39891260 PMC: 11786454. DOI: 10.1186/s12967-025-06153-7.


PET, SPECT, and MRI imaging for evaluation of Parkinson's disease.

Gujral J, Gandhi O, Singh S, Ahmed M, Ayubcha C, Werner T Am J Nucl Med Mol Imaging. 2025; 14(6):371-390.

PMID: 39840378 PMC: 11744359. DOI: 10.62347/AICM8774.


The proton resonance enhancement for CEST imaging and shift exchange (PRECISE) family of RF pulse shapes for CEST MRI.

Mohanta Z, Stabinska J, Gilad A, Barker P, McMahon M Magn Reson Med. 2025; 93(5):1954-1968.

PMID: 39831452 PMC: 11893253. DOI: 10.1002/mrm.30410.


Evaluation of Brain Impairment Using Proton Exchange Rate MRI in a Kainic Acid-Induced Rat Model of Epilepsy.

Yang H, Wu Q, Li L, Wu Y Mol Imaging Biol. 2025; 27(1):1-9.

PMID: 39747781 DOI: 10.1007/s11307-024-01980-4.


References
1.
Zhou J, Blakeley J, Hua J, Kim M, Laterra J, Pomper M . Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging. Magn Reson Med. 2008; 60(4):842-9. PMC: 2579754. DOI: 10.1002/mrm.21712. View

2.
Jones C, Polders D, Hua J, Zhu H, Hoogduin H, Zhou J . In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T. Magn Reson Med. 2011; 67(6):1579-89. PMC: 3291747. DOI: 10.1002/mrm.23141. View

3.
Varma G, Lenkinski R, Vinogradov E . Keyhole chemical exchange saturation transfer. Magn Reson Med. 2012; 68(4):1228-33. PMC: 3354034. DOI: 10.1002/mrm.23310. View

4.
Ling W, Regatte R, Navon G, Jerschow A . Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST). Proc Natl Acad Sci U S A. 2008; 105(7):2266-70. PMC: 2268124. DOI: 10.1073/pnas.0707666105. View

5.
Saar G, Zhang B, Ling W, Regatte R, Navon G, Jerschow A . Assessment of glycosaminoglycan concentration changes in the intervertebral disc via chemical exchange saturation transfer. NMR Biomed. 2012; 25(2):255-61. PMC: 3261499. DOI: 10.1002/nbm.1741. View