Evaluating of Small Intracranial Aneurysms by 64-detector CT Angiography: a Comparison with 3-dimensional Rotation DSA or Surgical Findings

Overview
Journal J Neuroimaging
Publisher Wiley
Specialties Neurology
Radiology
Date 2012 Dec 12
PMID 23228080
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated.

Methods: In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations.

Results: The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis.

Conclusion: The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative.

Citing Articles

Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings.

Yang L, Gao X, Gao C, Xu S, Cao S BMC Med Imaging. 2023; 23(1):161.

PMID: 37853358 PMC: 10585900. DOI: 10.1186/s12880-023-01107-1.


Accuracy of CT angiography for detecting ruptured intracranial aneurysms.

Mkhize N, Mngomezulu V, Buthelezi T SA J Radiol. 2023; 27(1):2636.

PMID: 37292420 PMC: 10244944. DOI: 10.4102/sajr.v27i1.2636.


Intra- and inter-observer variability in intracranial aneurysm segmentation: comparison between CT angiography (semi-automated segmentation software stroke VCAR) and digital subtraction angiography (3D rotational angiography).

DArgento F, Pedicelli A, Ciardi C, Leone E, Scarabello M, Infante A Radiol Med. 2020; 126(3):484-493.

PMID: 32902826 DOI: 10.1007/s11547-020-01275-y.


3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms--assessment of feasibility and image quality.

Westermaier T, Linsenmann T, Homola G, Loehr M, Stetter C, Willner N BMC Med Imaging. 2016; 16:30.

PMID: 27094510 PMC: 4837534. DOI: 10.1186/s12880-016-0133-0.


Intraoperative 3D rotational angiography: an emergency tool for the diagnosis of intracranial aneurysms.

Westermaier T, Willner N, Vince G, Linsenmann T, Ernestus R, Stetter C Emerg Radiol. 2014; 22(1):97-100.

PMID: 24989477 DOI: 10.1007/s10140-014-1252-y.