» Articles » PMID: 23224089

Comparison of Droplet Digital PCR to Real-time PCR for Quantitative Detection of Cytomegalovirus

Overview
Specialty Microbiology
Date 2012 Dec 11
PMID 23224089
Citations 128
Authors
Affiliations
Soon will be listed here.
Abstract

Quantitative real-time PCR (QRT-PCR) has been widely implemented for clinical viral load testing, but a lack of standardization and relatively poor precision have hindered its usefulness. Digital PCR offers highly precise, direct quantification without requiring a calibration curve. Performance characteristics of real-time PCR were compared to those of droplet digital PCR (ddPCR) for cytomegalovirus (CMV) load testing. Tenfold serial dilutions of the World Health Organization (WHO) and the National Institute of Standards and Technology (NIST) CMV quantitative standards were tested, together with the AcroMetrix CMV tc panel (Life Technologies, Carlsbad, CA) and 50 human plasma specimens. Each method was evaluated using all three standards for quantitative linearity, lower limit of detection (LOD), and accuracy. Quantitative correlation, mean viral load, and variability were compared. Real-time PCR showed somewhat higher sensitivity than ddPCR (LODs, 3 log(10) versus 4 log(10) copies/ml and IU/ml for NIST and WHO standards, respectively). Both methods showed a high degree of linearity and quantitative correlation for standards (R(2) ≥ 0.98 in each of 6 regression models) and clinical samples (R(2) = 0.93) across their detectable ranges. For higher concentrations, ddPCR showed less variability than QRT-PCR for the WHO standards and AcroMetrix standards (P < 0.05). QRT-PCR showed less variability and greater sensitivity than did ddPCR in clinical samples. Both digital and real-time PCR provide accurate CMV load data over a wide linear dynamic range. Digital PCR may provide an opportunity to reduce the quantitative variability currently seen using real-time PCR, but methods need to be further optimized to match the sensitivity of real-time PCR.

Citing Articles

Establishment of a Sensitive and Reliable Droplet Digital PCR Assay for the Detection of .

Su Y, Zhu X, Jing H, Yu H, Liu H Plants (Basel). 2024; 13(19).

PMID: 39409571 PMC: 11478728. DOI: 10.3390/plants13192701.


Robust Double Emulsions for Multicolor Fluorescence-Activated Cell Sorting.

Ding Y, Zoppi G, Antonini G, Geiger R, deMello A Anal Chem. 2024; 96(37):14809-14818.

PMID: 39231502 PMC: 11411495. DOI: 10.1021/acs.analchem.4c02363.


Serological and Molecular Detection of Citrus Tristeza Virus: A Review.

Shang P, Xu L, Cheng T Microorganisms. 2024; 12(8).

PMID: 39203383 PMC: 11356770. DOI: 10.3390/microorganisms12081539.


Sensitive and Accurate Quantification of Enterovirus-D68 (EV-D68) Viral Loads Using Droplet Digital PCR (ddPCR).

Grizer C, Li Z, Mattapallil J Microorganisms. 2024; 12(8).

PMID: 39203345 PMC: 11356211. DOI: 10.3390/microorganisms12081502.


Developing centrifugal force real-time digital PCR for detecting extremely low DNA concentration.

Shin J, Jeong J, Son S, Choi S, Nam H, Yoon T Sci Rep. 2024; 14(1):11522.

PMID: 38769102 PMC: 11636855. DOI: 10.1038/s41598-024-62199-5.


References
1.
Zimmermann B, Grill S, Holzgreve W, Zhong X, Jackson L, Hahn S . Digital PCR: a powerful new tool for noninvasive prenatal diagnosis?. Prenat Diagn. 2008; 28(12):1087-93. DOI: 10.1002/pd.2150. View

2.
Hayden R, Yan X, Wick M, Rodriguez A, Xiong X, Ginocchio C . Factors contributing to variability of quantitative viral PCR results in proficiency testing samples: a multivariate analysis. J Clin Microbiol. 2011; 50(2):337-45. PMC: 3264161. DOI: 10.1128/JCM.01287-11. View

3.
Sanders R, Huggett J, Bushell C, Cowen S, Scott D, Foy C . Evaluation of digital PCR for absolute DNA quantification. Anal Chem. 2011; 83(17):6474-84. DOI: 10.1021/ac103230c. View

4.
Vesper H, Miller W, Myers G . Reference materials and commutability. Clin Biochem Rev. 2008; 28(4):139-47. PMC: 2282402. View

5.
Pohl G, Shih I . Principle and applications of digital PCR. Expert Rev Mol Diagn. 2004; 4(1):41-7. DOI: 10.1586/14737159.4.1.41. View