» Articles » PMID: 23220766

X-ray Phase-contrast Imaging: from Pre-clinical Applications Towards Clinics

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2012 Dec 11
PMID 23220766
Citations 201
Authors
Affiliations
Soon will be listed here.
Abstract

Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.

Citing Articles

Visualization of the hatching of brine shrimp eggs using ultrafast and high-resolution phase-contrast CTs.

Tang R, Fu Y, Li K, Wang F, Chen K APL Bioeng. 2025; 9(1):016113.

PMID: 40060158 PMC: 11890158. DOI: 10.1063/5.0238482.


From morphology to single-cell molecules: high-resolution 3D histology in biomedicine.

Xu X, Su J, Zhu R, Li K, Zhao X, Fan J Mol Cancer. 2025; 24(1):63.

PMID: 40033282 PMC: 11874780. DOI: 10.1186/s12943-025-02240-x.


The use of ethanol as contrast enhancer in synchrotron X-ray phase-contrast imaging leads to heterogeneous myocardial tissue shrinkage: a case report.

Bernardino G, Calvet-Mirabent A, Dejea H, Guasch E, Bonnin A, Garcia-Canadilla P J Synchrotron Radiat. 2024; 32(Pt 1):200-209.

PMID: 39689036 PMC: 11708853. DOI: 10.1107/S1600577524010221.


Using X-ray velocimetry to measure lung function and assess the efficacy of a pseudomonas aeruginosa bacteriophage therapy for cystic fibrosis.

Harker S, Preissner M, Chang R, Trevascus D, Liu C, Wang Y Sci Rep. 2024; 14(1):29727.

PMID: 39614107 PMC: 11607086. DOI: 10.1038/s41598-024-80326-0.


Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources.

Harke K, Armstrong M, Martinez D, Lind J, Kumar M Sci Rep. 2024; 14(1):25580.

PMID: 39461985 PMC: 11514004. DOI: 10.1038/s41598-024-76444-4.