Group level statistical maps of blood oxygenation level dependent (BOLD) signals acquired using functional magnetic resonance imaging (fMRI) have become a basic measurement for much of systems, cognitive and social neuroscience. A challenge in making inferences from these statistical maps is the noise and potential confounds that arise from the head motion that occurs within and between acquisition volumes. This motion results in the scan plane being misaligned during acquisition, ultimately leading to reduced statistical power when maps are constructed at the group level. In most cases, an attempt is made to correct for this motion through the use of retrospective analysis methods. In this paper, we use a prospective active marker motion correction (PRAMMO) system that uses radio frequency markers for real-time tracking of motion, enabling on-line slice plane correction. We show that the statistical power of the activation maps is substantially increased using PRAMMO compared to conventional retrospective correction. Analysis of our results indicates that the PRAMMO acquisition reduces the variance without decreasing the signal component of the BOLD (beta). Using PRAMMO could thus improve the overall statistical power of fMRI based BOLD measurements, leading to stronger inferences of the nature of processing in the human brain.

Citing Articles

Reliability and validity of brain-gastric phase synchronization.

Levakov G, Ganor S, Avidan G Hum Brain Mapp. 2023; 44(14):4956-4966.

PMID: 37528686 PMC: 10472921. DOI: 10.1002/hbm.26436.


Quality control in resting-state fMRI: the benefits of visual inspection.

Lepping R, Yeh H, McPherson B, Brucks M, Sabati M, Karcher R Front Neurosci. 2023; 17:1076824.

PMID: 37214404 PMC: 10192849. DOI: 10.3389/fnins.2023.1076824.


Resting State fMRI: Going Through the Motions.

Maknojia S, Churchill N, Schweizer T, Graham S Front Neurosci. 2019; 13:825.

PMID: 31456656 PMC: 6700228. DOI: 10.3389/fnins.2019.00825.


Prospective motion correction improves the sensitivity of fMRI pattern decoding.

Huang P, Carlin J, Alink A, Kriegeskorte N, Henson R, Correia M Hum Brain Mapp. 2018; 39(10):4018-4031.

PMID: 29885014 PMC: 6175330. DOI: 10.1002/hbm.24228.


Reduction of Motion Artifacts and Noise Using Independent Component Analysis in Task-Based Functional MRI for Preoperative Planning in Patients with Brain Tumor.

Middlebrooks E, Frost C, Tuna I, Schmalfuss I, Rahman M, Old Crow A AJNR Am J Neuroradiol. 2017; 38(2):336-342.

PMID: 28056453 PMC: 7963830. DOI: 10.3174/ajnr.A4996.


References
1.
Calhoun V, Maciejewski P, Pearlson G, Kiehl K . Temporal lobe and "default" hemodynamic brain modes discriminate between schizophrenia and bipolar disorder. Hum Brain Mapp. 2007; 29(11):1265-75. PMC: 2665178. DOI: 10.1002/hbm.20463. View

2.
Pipe J . Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999; 42(5):963-9. DOI: 10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l. View

3.
Ward H, Riederer S, Grimm R, Ehman R, Felmlee J, Jack Jr C . Prospective multiaxial motion correction for fMRI. Magn Reson Med. 2000; 43(3):459-69. DOI: 10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19>3.0.co;2-1. View

4.
Krueger S, Wolff S, Schmitgen A, Timinger H, Bublat M, Schaeffter T . Fast and accurate automatic registration for MR-guided procedures using active microcoils. IEEE Trans Med Imaging. 2007; 26(3):385-92. DOI: 10.1109/TMI.2006.889748. View

5.
Ehman R, Felmlee J . Adaptive technique for high-definition MR imaging of moving structures. Radiology. 1989; 173(1):255-63. DOI: 10.1148/radiology.173.1.2781017. View