Problems Associated with Identification of Legionella Species from the Environment and Isolation of Six Possible New Species
Overview
Microbiology
Affiliations
Following investigation of an outbreak of legionellosis in South Australia, numerous Legionella-like organisms were isolated from water samples. Because of the limited number of commercially available direct fluorescent-antibody reagents and the cross-reactions found with some reagents, non-pneumophila legionellae proved to be difficult to identify and these isolates were stored at -70 degrees C for later study. Latex agglutination reagents for Legionella pneumophila and Legionella anisa developed by the Institute of Medical and Veterinary Science, Adelaide, Australia, were found to be useful as rapid screening aids. Autofluorescence was useful for placing isolates into broad groups. Cellular fatty acid analysis, ubiquinone analysis, and DNA hybridization techniques were necessary to provide definitive identification. The species which were isolated most frequently were L. pneumophila, followed by L. anisa, Legionella jamestowniensis, Legionella quinlivanii, Legionella rubrilucens, Legionella spiritensis, and a single isolate each of Legionella erythra, Legionella jordanis, Legionella birminghamensis, and Legionella cincinnatiensis. In addition, 10 isolates were found by DNA hybridization studies to be unrelated to any of the 26 currently known species, representing what we believe to be 6 possible new species.
The Contribution of to Contamination of Water in the Built Environment.
Crook B, Young C, Rideout C, Smith D Int J Environ Res Public Health. 2024; 21(8).
PMID: 39200710 PMC: 11354164. DOI: 10.3390/ijerph21081101.
strain isolated from a human: A case report and whole genome sequencing analysis.
Lalancette C, Leduc J, Malo J, Fournier E, Saoud J, Faucher S J Assoc Med Microbiol Infect Dis Can. 2022; 5(2):112-114.
PMID: 36338178 PMC: 9602882. DOI: 10.3138/jammi-2019-0021.
Current and emerging Legionella diagnostics for laboratory and outbreak investigations.
Mercante J, Winchell J Clin Microbiol Rev. 2015; 28(1):95-133.
PMID: 25567224 PMC: 4284297. DOI: 10.1128/CMR.00029-14.
Legionella anisa, a possible indicator of water contamination by Legionella pneumophila.
van der Mee-Marquet N, Domelier A, Arnault L, Bloc D, Laudat P, Hartemann P J Clin Microbiol. 2006; 44(1):56-9.
PMID: 16390948 PMC: 1351956. DOI: 10.1128/JCM.44.1.56-59.2006.
De Gheldre Y, Maes N, Presti F, Etienne J, Struelens M J Clin Microbiol. 2001; 39(1):162-9.
PMID: 11136765 PMC: 87696. DOI: 10.1128/JCM.39.1.162-169.2001.