Objective: The purpose of this study was to assess the value of dual-source dual-energy CT in the evaluation of complex cystic renal masses.

Subjects And Methods: Seventy patients underwent contrast-enhanced dual-energy CT that included true unenhanced images acquired in single-energy mode, corticomedullary phase images acquired in dual-energy mode, and nephrographic phase images acquired in single-energy mode. Virtual unenhanced, blended weighted-average, and color-coded iodine overlay images were reconstructed. The acceptance level and image quality of virtual and true unenhanced images were evaluated. Contrast enhancement on both true unenhanced or blended weighted-average images and color-coded iodine overlay images was evaluated with both calculation in regions of interest and use of confidence level scales. Radiation dose parameters were estimated.

Results: Virtual unenhanced images of 70 lesions (97.2%) and true unenhanced images of 72 lesions (100%) were judged acceptable (p = 0.5). The mean quality score of virtual unenhanced images was 2.0 ± 0.7 and of true unenhanced images was 1.5 ± 0.5 (p < 0.001). Mean contrast enhancement measured on true unenhanced and blended weighted-average images was 45.9 ± 15.9 HU (range, 21-78 HU) and on color-coded iodine overlay images was 47.3 ± 16.8 HU (range, 22-75 HU) with no significant differences. Enhancement was excluded on color-coded iodine overlay images with a significantly (p < 0.03) higher level of confidence than it was on true unenhanced and blended weighted-average images. The mean dose reduction with use of a combined dual- and single-energy dual-phase CT protocol was 29.1% ± 11.9% (p < 0.001).

Conclusion: Dual-source dual-energy CT is a reliable imaging technique in the evaluation of complex cystic renal masses. True unenhanced images can be replaced by virtual unenhanced images with considerable radiation dose reduction. The color-coded iodine overlay technique is a useful tool for both excluding and identifying endocystic enhancement.

Citing Articles

Computed Tomography Urography: State of the Art and Beyond.

Cellina M, Ce M, Rossini N, Cacioppa L, Ascenti V, Carrafiello G Tomography. 2023; 9(3):909-930.

PMID: 37218935 PMC: 10204399. DOI: 10.3390/tomography9030075.


Dual-energy computed tomography of the abdomen: A reliable trouble-shooter.

Chidambaram V, Choong M, Goud C J Clin Imaging Sci. 2023; 13:12.

PMID: 37152441 PMC: 10159281. DOI: 10.25259/JCIS_25_2023.


An evaluation of the contribution of routine ultrasound when performed with multiphase CT in renal donor imaging assessment.

Towfighi S, Bajaj S, Aggarwal T, Nguan C, Pang E Eur Radiol. 2023; 33(9):6592-6598.

PMID: 37017701 DOI: 10.1007/s00330-023-09578-0.


Use of dual energy CT urography in evaluation of urinary stone and complex cyst.

Gezer M, Karaca L, Ozdemir Z, Kahraman A, Oguz F, Erbay M Turk J Med Sci. 2023; 53(1):264-272.

PMID: 36945947 PMC: 10388052. DOI: 10.55730/1300-0144.5581.


Recent advances in imaging techniques of renal masses.

Aggarwal A, Das C, Sharma S World J Radiol. 2022; 14(6):137-150.

PMID: 35978979 PMC: 9258310. DOI: 10.4329/wjr.v14.i6.137.