A Multiplanar Radiography Method for Assessing Cup Orientation in Total Hip Arthroplasty

Overview
Journal J Biomech Eng
Date 2012 Oct 23
PMID 23083199
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Correct orientation of the acetabular cup considering patient-specific functional pelvic angles is an important factor for improving outcomes and avoiding complications after total hip arthroplasty. This study introduces a new, noninvasive radiographic tool for accurately determining a patient's specific pelvic tilt angle preoperatively, as well as accurately assessing acetabular cup orientation with respect to bony landmarks intraoperatively and postoperatively. The method was validated by imaging a bone replica model of the pelvis with implanted hip components, in comparison to digitized references, and verified with a cadaveric specimen. Pelvic tilt was measured with an accuracy of 0.1 deg and SD of 0.4 deg. Operative cup inclination and anteversion showed accuracies of 0.6 deg and 2.5 deg, with SD of 0.4 deg and 0.6 deg, respectively; these could be improved further by subtracting systematic bias. The method shows accuracy advantages over existing radiographic and fluoroscopic methods and exposes the subjects to a lower radiation dose compared to the similar computed tomography methods. These results suggest that the proposed method is feasible for assessing cup placement with reference to the functional and anatomical references. Furthermore, the ability to reference the same bony landmarks preoperatively, intraoperatively, and postoperatively has important research and clinical advantages.

Citing Articles

Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Zhao J, Su X, Zhao Z, Xiao R, Zhang L, Tang P Ann Transl Med. 2020; 8(4):130.

PMID: 32175423 PMC: 7049040. DOI: 10.21037/atm.2019.12.150.


The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Zhao J, Su X, Zhao Z, Xiao R, Sun G, Zhang L Med Biol Eng Comput. 2019; 57(11):2359-2371.

PMID: 31502181 DOI: 10.1007/s11517-019-02041-7.


Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

Zhao J, Su X, Zhao Z, Xiao R, Zhang L, Tang P Int Orthop. 2018; 42(8):1819-1825.

PMID: 29453586 DOI: 10.1007/s00264-018-3809-y.


A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

Amiri S, Wilson D, Masri B, Anglin C Int J Comput Assist Radiol Surg. 2013; 9(4):695-711.

PMID: 24323400 DOI: 10.1007/s11548-013-0957-9.