» Articles » PMID: 23067875

Repeatability, Variability and Reference Values of Pulsed Wave Doppler Echocardiographic Measurements in Healthy Saanen Goats

Overview
Journal BMC Vet Res
Publisher Biomed Central
Date 2012 Oct 17
PMID 23067875
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established.

Results: As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats.

Conclusions: PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research.

Citing Articles

Novel color M-mode echocardiography for non-invasive assessment of the intraventricular pressure in goats: Feasibility, repeatability, and the effect of sedation.

Mandour A, Samir H, Yoshida T, Matsuura K, Hamabe L, Shimada K Front Vet Sci. 2022; 9:935437.

PMID: 36277071 PMC: 9582648. DOI: 10.3389/fvets.2022.935437.


Pulsed wave Doppler echocardiographic assessment after sedation by intravenous injection of medetomidine and xylazine hydrochloride on cardiac output and systolic time intervals in one-humped camel calves ().

Masoudifard M, Esmailinejad M, Sakhaee E, Azari O, Vafaei R, Ghalekhani N Iran J Vet Res. 2021; 21(4):257-262.

PMID: 33584837 PMC: 7871738.


Assessment of the Cardiac Functions Using Full Conventional Echocardiography with Tissue Doppler Imaging before and after Xylazine Sedation in Male Shiba Goats.

Mandour A, Samir H, Yoshida T, Matsuura K, Abdelmageed H, Elbadawy M Animals (Basel). 2020; 10(12).

PMID: 33297474 PMC: 7762359. DOI: 10.3390/ani10122320.


Two-dimensional speckle tracking echocardiography in goats: repeatability, variability, and validation of the technique using an exercise test and an experimentally induced acute ischemic cardiomyopathy.

Leroux A, Moonen M, Farnir F, Deleuze S, Sandersen C, Amory H BMC Vet Res. 2020; 16(1):56.

PMID: 32059677 PMC: 7023799. DOI: 10.1186/s12917-020-02277-8.


Reference intervals of echocardiographic measurements in healthy adult dairy goats.

Szalus-Jordanow O, Czopowicz M, Witkowski L, Mickiewicz M, Frymus T, Markowska-Daniel I PLoS One. 2017; 12(8):e0183293.

PMID: 28829836 PMC: 5567658. DOI: 10.1371/journal.pone.0183293.


References
1.
Santilli R, Bussadori C . Doppler echocardiographic study of left ventricular diastole in non-anaesthetized healthy cats. Vet J. 1999; 156(3):203-15. DOI: 10.1016/s1090-0233(98)80124-x. View

2.
Kriz N, Rose R . Repeatability of standard transthoracic echocardiographic measurements in horses. Aust Vet J. 2002; 80(6):362-70. DOI: 10.1111/j.1751-0813.2002.tb14790.x. View

3.
Simpson K, Devine B, Gunn-Moore D, French A, Dukes-McEwan J, Koffas H . Assessment of the repeatability of feline echocardiography using conventional echocardiography and spectral pulse-wave Doppler tissue imaging techniques. Vet Radiol Ultrasound. 2007; 48(1):58-68. DOI: 10.1111/j.1740-8261.2007.00205.x. View

4.
Hallowell G, Potter T, Bowen I . Methods and normal values for echocardiography in adult dairy cattle. J Vet Cardiol. 2007; 9(2):91-8. DOI: 10.1016/j.jvc.2007.10.001. View

5.
Disatian S, Bright J, Boon J . Association of age and heart rate with pulsed-wave Doppler measurements in healthy, nonsedated cats. J Vet Intern Med. 2008; 22(2):351-6. DOI: 10.1111/j.1939-1676.2008.0066.x. View