» Articles » PMID: 23064594

Pipeline Embolization Device in Aneurysmal Subarachnoid Hemorrhage

Overview
Specialty Neurology
Date 2012 Oct 16
PMID 23064594
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: The PED is an FDS designed for the treatment of intracranial aneurysms. Data regarding the use of this device in acute or subacute aSAH is limited to a few case reports or small series. We aimed to demonstrate the feasibility of using an FDS, the PED, for the treatment of ruptured intracranial aneurysms with challenging morphologies.

Materials And Methods: We conducted a retrospective review of all known patients treated with the PED for aSAH at 4 institutions between June 2008 and January 2012. Pertinent clinical and radiologic information was submitted by individual centers for central collation. The decision to treat with the PED was made on a case-by-case basis by a multidisciplinary team under compassionate use.

Results: Twenty patients (15 women; median age, 54.5 years; IQR, 8.0 years) were found. There were 8 blister, 8 dissecting or dysplastic, 2 saccular, and 2 giant aneurysms. Median time to treatment was 4 days (range, 1-90 days; IQR, 12.75 days) from rupture. Three patients had previous failed treatment. Procedure-related symptomatic morbidity and mortality were 15%, with 1 (5%) procedure-related death. Two patients died relative to medical complications, and 1 patient was lost to follow-up. Sixteen patients were available for follow-up, 81% had a GOS of 5, and 13% had a GOS of 4 attributed to a poorer initial clinical presentation. One patient died of urosepsis at 4 months. Occlusion rates were 75% and 94% at 6 months and 12 months, respectively. There were 3 delayed complications (1 silent perforator infarct, 2 moderate asymptomatic in-stent stenoses). No symptomatic delayed complications or rehemorrhages occurred.

Conclusions: The FDS may be a feasible treatment option in the acute or subacute setting of selected ruptured aneurysms, especially blister aneurysms. Ruptured giant aneurysms remain challenging for both surgical and endovascular techniques; at this stage, FDSs should be used with caution in this aneurysm subtype.

Citing Articles

Safety and efficacy of the pipeline embolization device for treatment of small vs. large aneurysms: a systematic review and meta-analysis.

Ghaith A, Greco E, Rios-Zermeno J, El-Hajj V, Perez-Vega C, Ghanem M Neurosurg Rev. 2023; 46(1):284.

PMID: 37882896 DOI: 10.1007/s10143-023-02192-0.


Endoluminal flow diversion as a primary treatment strategy for pediatric traumatic intracranial aneurysms: a case-based review of literature.

Mohammad Hosseini E, Zafarshamspour S, Ghasemi-Rad M, Benndorf G, Rasekhi A, Rafieossadat R Childs Nerv Syst. 2023; 40(2):345-357.

PMID: 37750891 DOI: 10.1007/s00381-023-06161-2.


GPR30 agonist G1 combined with hypothermia alleviates cognitive impairment and anxiety-like behavior after subarachnoid hemorrhage in rats.

Peng J, He Y, He J, Zhang J, Yu Z, Xia Y Brain Behav. 2023; 13(10):e3204.

PMID: 37548479 PMC: 10570468. DOI: 10.1002/brb3.3204.


Vertebral artery dissection and associated ruptured intracranial pseudoaneurysm successfully treated with coil assisted flow diversion: A case report and review of the literature.

Scullen T, Mathkour M, Werner C, Zeoli T, Amenta P Brain Circ. 2021; 7(3):159-166.

PMID: 34667899 PMC: 8459696. DOI: 10.4103/bc.bc_67_20.


Neurosurgical management of aneurysms of the vertebrobasilar system: increasing indications for endovascular therapy with a continued role for open microneurosurgery.

Larson A, Mehta T, Grande A Neurosurg Rev. 2021; 44(5):2469-2476.

PMID: 33409762 DOI: 10.1007/s10143-020-01460-7.


References
1.
Khurana V, Piepgras D, Whisnant J . Ruptured giant intracranial aneurysms. Part I. A study of rebleeding. J Neurosurg. 1998; 88(3):425-9. DOI: 10.3171/jns.1998.88.3.0425. View

2.
Dai D, Ding Y, Kadirvel R, Rad A, Lewis D, Kallmes D . Patency of branches after coverage with multiple telescoping flow-diverter devices: an in vivo study in rabbits. AJNR Am J Neuroradiol. 2011; 33(1):171-4. PMC: 7966178. DOI: 10.3174/ajnr.A2879. View

3.
Chow M, McDougall C, OKelly C, Ashforth R, Johnson E, Fiorella D . Delayed spontaneous rupture of a posterior inferior cerebellar artery aneurysm following treatment with flow diversion: a clinicopathologic study. AJNR Am J Neuroradiol. 2011; 33(4):E46-51. PMC: 8050442. DOI: 10.3174/ajnr.A2532. View

4.
Rasskazoff S, Silvaggio J, Brouwer P, Kaufmann A, Nistor A, Iancu D . Endovascular treatment of a ruptured blood blister-like aneurysm with a flow-diverting stent. Interv Neuroradiol. 2010; 16(3):255-8. PMC: 3277995. DOI: 10.1177/159101991001600304. View

5.