» Articles » PMID: 22995721

Transplantation of Initially Rejected Donor Lungs After Ex Vivo Lung Perfusion

Overview
Date 2012 Sep 22
PMID 22995721
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Ex vivo lung perfusion has the potential to increase the number of patients treated with lung transplantation. Our initial clinical experience with ex vivo lung perfusion is reviewed as well as early clinical outcome in patients transplanted with reconditioned lungs.

Methods: Six pairs of donor lungs deemed unsuitable for transplantation underwent ex vivo lung perfusion with Steen solution mixed with red blood cells to a hematocrit of 10% to 15%. After reconditioning, lung function was evaluated and acceptable lungs were transplanted. Technical experience with ex vivo lung perfusion as well as clinical outcome for patients transplanted with ex vivo lung perfusion-treated lungs were evaluated.

Results: Donor lungs initially rejected either as a result of an inferior partial pressure of arterial oxygen/ fraction of inspired oxygen (n = 5; mean, 20.5 kPa; range, 9.1-29.9 kPa) or infiltrate on chest radiograph (n = 1) improved their oxygenation capacity to a mean partial pressure of arterial oxygen/fraction of inspired oxygen of 57 ± 10 kPa during the ex vivo lung perfusion (mean improvement, 33.6 kPa; range, 21-51 kPa; P < .01). During evaluation, hemodynamic (flow, vascular resistance, pressure) and respiratory (peak airway pressure, compliance) parameters were stable. Two single lungs were not used for lung transplantation because of subpleural hematoma or edema. Six recipients from the regular waiting list underwent single (n = 2) or double (n = 4) lung transplantation. One patient had primary graft dysfunction grade 2 at 72 hours. Median time to extubation was 7 hours. All patients survived 30 days and were discharged in good condition from the hospital.

Conclusions: The use of ex vivo lung perfusion seems safe and indicates that some lungs otherwise refused for lung transplantation can be recovered and transplanted with acceptable short-term results.

Citing Articles

The impact and relevance of techniques and fluids on lung injury in machine perfusion of lungs.

Ponholzer F, Dumfarth J, Krapf C, Pircher A, Hautz T, Wolf D Front Immunol. 2024; 15:1358153.

PMID: 38510260 PMC: 10950925. DOI: 10.3389/fimmu.2024.1358153.


Recovery of extracorporeal lungs using cross-circulation with injured recipient swine.

Chen P, Van Hassel J, Pinezich M, Diane M, Hudock M, Kaslow S J Thorac Cardiovasc Surg. 2023; 167(5):e106-e130.

PMID: 37741314 PMC: 10954590. DOI: 10.1016/j.jtcvs.2023.09.032.


Development of a cost-effective lung perfusion system for lung transplantation in India.

Ganesan R, Kajal K, Singh H, Das A, Kaur R, Saini N Indian J Med Res. 2022; 155(2):293-300.

PMID: 35946207 PMC: 9629529. DOI: 10.4103/ijmr.IJMR_27_19.


Optical oxygen saturation imaging in cellular ex vivo lung perfusion to assess lobular pulmonary function.

Sakota D, Kosaka R, Niikawa H, Ohuchi K, Arai H, McCurry K Biomed Opt Express. 2022; 13(1):328-343.

PMID: 35154874 PMC: 8803022. DOI: 10.1364/BOE.445021.


Transcriptional analysis identifies potential novel biomarkers associated with successful ex-vivo perfusion of human donor lungs.

Ferdinand J, Morrison M, Andreasson A, Charlton C, Chhatwal A, Scott 3rd W Clin Transplant. 2021; 36(4):e14570.

PMID: 34954872 PMC: 9285052. DOI: 10.1111/ctr.14570.