» Articles » PMID: 22885159

Preoperative Agreement on the Geometric Classification and 2-dimensional Measurement of Rotator Cuff Tears Based on Magnetic Resonance Arthrography

Overview
Journal Arthroscopy
Specialty Orthopedics
Date 2012 Aug 14
PMID 22885159
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine the intraobserver and interobserver agreement on the geometric classification and 2-dimensional measurements of rotator cuff tears based on magnetic resonance arthrography.

Methods: We retrospectively reviewed preoperative magnetic resonance arthrograms of 73 consecutive patients who were surgically treated for their full-thickness rotator cuff tears. The images were blinded and evaluated by 2 orthopaedic shoulder surgeons and 2 musculoskeletal radiologists using the geometric classification of rotator cuff tears (type 1, crescent-shaped tear; type 2, longitudinal U- or L-shaped tear; type 3a, massive tear measuring between 20 and 30 mm; and type 3b, massive contracted tear measuring >30 mm) and measuring the sagittal/coronal dimensions of the tear. Review was performed twice with an interval of at least 8 weeks. Agreement was calculated using the linear weighted κ coefficient and the intraclass correlation coefficient (ICC).

Results: The intraobserver agreement was excellent for both the geometric classification and the sagittal/coronal dimension measurement (κ, 0.81 to 0.92; ICC, 0.84 to 0.98). The ICC for the interobserver agreement was excellent for all sagittal and coronal dimension measurements (ICC, 0.95 to 0.97). The interobserver agreement for the geometric classification was good for the orthopaedic surgeons (κ, 0.75 for round 1 and 0.73 for round 2). The interobserver agreement for the radiologists was excellent in observation round 1 (κ, 0.82) and good in observation round 2 (κ, 0.71). The interobserver agreement between orthopaedic surgeons and radiologists was found to be moderate to good (κ, 0.52 to 0.66). The Fleiss κ was 0.66 for round 1 and 0.62 for round 2.

Conclusions: The geometric classification and the 2-dimensional measurement of rotator cuff tears using magnetic resonance arthrography have good to excellent intraobserver agreement and moderate to good interobserver agreement among experienced observers.

Level Of Evidence: Level III, diagnostic study of nonconsecutive patients without consistently applied gold standard.

Citing Articles

Clinical value of three-dimensional ultrasonography in the morphologic evaluation of rotator cuff tear: a prospective study.

Chen X, Wang Y, Chen J, Zhang F, Xu L, Yan X Eur Radiol. 2022; 33(4):2331-2339.

PMID: 36418625 DOI: 10.1007/s00330-022-09213-4.


Can deep learning reduce the time and effort required for manual segmentation in 3D reconstruction of MRI in rotator cuff tears?.

Kim H, Shin K, Kim H, Lee E, Chung S, Koh K PLoS One. 2022; 17(10):e0274075.

PMID: 36215291 PMC: 9550047. DOI: 10.1371/journal.pone.0274075.


Magnetic resonance imaging reproducibility for rotator cuff partial tears in patients up to 60 years.

Yazigi Junior J, Anauate Nicolao F, Netto N, Matsunaga F, Lim Lee J, Ogata S BMC Musculoskelet Disord. 2019; 20(1):383.

PMID: 31431192 PMC: 6702712. DOI: 10.1186/s12891-019-2760-4.


Multivariate analyses of rotator cuff pathologies in shoulder disability.

Henseler J, Raz Y, Nagels J, van Zwet E, Raz V, Nelissen R PLoS One. 2015; 10(2):e0118158.

PMID: 25710703 PMC: 4339721. DOI: 10.1371/journal.pone.0118158.


Scaffolds for tendon and ligament repair and regeneration.

Ratcliffe A, Butler D, Dyment N, Cagle Jr P, Proctor C, Ratcliffe S Ann Biomed Eng. 2015; 43(3):819-31.

PMID: 25650098 PMC: 4380768. DOI: 10.1007/s10439-015-1263-1.