» Articles » PMID: 22855850

The Use of Dual-mobility Components in Total Hip Arthroplasty

Overview
Publisher Wolters Kluwer
Date 2012 Aug 3
PMID 22855850
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Dual-mobility hip components provide for an additional articular surface, with the goal of improving range of motion, jump distance (ie, vertical or inferior head displacement required for dislocation), and stability of the total hip arthroplasty. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit within the polyethylene. New components have recently been released for use in North America. Although these devices are routinely used in some European centers for primary hip arthroplasty, their greatest utility may be to manage recurrent dislocation in the setting of revision hip arthroplasty. Several small retrospective series have shown satisfactory results for this indication at short- to midterm follow-up. Polyethylene wear and intraprosthetic dislocation are concerns, as is the lack of long-term data. Caution is thus advised in the routine use of dual-mobility components in primary and revision total hip arthroplasty.

Citing Articles

Intraprosthetic Dislocation Following Dual Mobility Total Hip Arthroplasty: A Retrieval Analysis Study.

Sobhi S, Kop A, Pabbruwe M, Jones C, Finsterwald M Arthroplast Today. 2025; 31():101596.

PMID: 39811773 PMC: 11732184. DOI: 10.1016/j.artd.2024.101596.


Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review.

Ciolli G, Mesnard G, Deroche E, Gunst S, Batailler C, Servien E J Pers Med. 2023; 13(1).

PMID: 36675742 PMC: 9867154. DOI: 10.3390/jpm13010081.


Which femoral neck for a dual mobility cup? A biomechanical evaluation.

Wegrzyn J, Longaray J, Baez R, Herrera L Int Orthop. 2022; 46(8):1783-1793.

PMID: 35570206 PMC: 9349148. DOI: 10.1007/s00264-022-05415-z.


Tripolar Constrained and Dual Mobility Liners Are Both Successful When Cemented Into Tantalum Acetabular Revision Shells in Complex Revision Total Hip Arthroplasty.

Valenzuela J, Bergman N, Hiscock R Arthroplast Today. 2022; 14:53-58.

PMID: 35242957 PMC: 8881686. DOI: 10.1016/j.artd.2021.12.011.


Intraprosthetic Dislocation of Dual-Mobility Total Hip Arthroplasty: The Unforeseen Complication.

Hermena S, Tawfeek W, Latimer P Cureus. 2021; 13(11):e19858.

PMID: 34963863 PMC: 8705880. DOI: 10.7759/cureus.19858.