Abstract

Objective: 20 % of patients with a systemic RV are pacemaker dependent, and unsuitable to undergo cardiac magnetic resonance (CMR). Multidetector row computed tomography (MDCT) could provide a reproducible alternative to CMR in these patients. The aim of this study was to compare variability of MDCT with CMR.

Methods: Thirty-five patients with systemic RV underwent either MDCT (n = 15) or CMR (n = 20). Systemic RV volumes and ejection fraction were obtained, and intra- and interobserver variability for both modalities were assessed and compared.

Results: We found the intra- and interobserver variability of volumes and function measurements of the systemic RV obtained with MDCT to be higher compared with those obtained with CMR. However, these differences in variability were not significant, the only exception being the interobserver variability of systemic RV stroke volume.

Conclusions: MDCT provides a reproducible alternative to CMR for volumes and function assessment in patients with a systemic RV.

Citing Articles

Knowledge-based 3D reconstruction of the right ventricle: comparison with cardiac magnetic resonance in adults with congenital heart disease.

Trzebiatowska-Krzynska A, Driessen M, Sieswerda G, Wallby L, Swahn E, Meijboom F Echo Res Pract. 2016; 2(4):109-16.

PMID: 26796613 PMC: 4677647. DOI: 10.1530/ERP-15-0029.


The right ventricle: always normal in normal subjects?.

van der Wall E Neth Heart J. 2014; 23(1):62-3.

PMID: 25492108 PMC: 4268211. DOI: 10.1007/s12471-014-0640-y.


Screening in asymptomatic coronary artery disease: helpful, redundant or harmful?.

van der Wall E Neth Heart J. 2014; 22(12):531-2.

PMID: 25326101 PMC: 4391182. DOI: 10.1007/s12471-014-0614-0.


A GPS map for pulmonary hypertension: a review of imaging modalities.

Li J, Lee A, Cheng Y Curr Hypertens Rep. 2013; 15(6):650-8.

PMID: 24136329 DOI: 10.1007/s11906-013-0392-x.


Crown years for non-invasive cardiovascular imaging (Part IV): 30 years of cardiac computed tomography.

van der Wall E Neth Heart J. 2013; 21(7-8):315-8.

PMID: 23640578 PMC: 3722385. DOI: 10.1007/s12471-013-0427-6.


References
1.
Mayo J, Leipsic J . Radiation dose in cardiac CT. AJR Am J Roentgenol. 2009; 192(3):646-53. DOI: 10.2214/AJR.08.2066. View

2.
Dodge-Khatami A, Tulevski I, Bennink G, Hitchcock J, de Mol B, van der Wall E . Comparable systemic ventricular function in healthy adults and patients with unoperated congenitally corrected transposition using MRI dobutamine stress testing. Ann Thorac Surg. 2002; 73(6):1759-64. DOI: 10.1016/s0003-4975(02)03553-1. View

3.
Grothues F, Moon J, Bellenger N, Smith G, Klein H, Pennell D . Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J. 2004; 147(2):218-23. DOI: 10.1016/j.ahj.2003.10.005. View

4.
Engelfriet P, Boersma E, Oechslin E, Tijssen J, Gatzoulis M, Thilen U . The spectrum of adult congenital heart disease in Europe: morbidity and mortality in a 5 year follow-up period. The Euro Heart Survey on adult congenital heart disease. Eur Heart J. 2005; 26(21):2325-33. DOI: 10.1093/eurheartj/ehi396. View

5.